Product comparison · 2 uninterruptible power supplies (upss)

APC SUA5000RMI5U + WBEXTWAR3YR-SP-05 vs Vertiv GXT3-MT On-Line UPS, 1000VA

Add a product
  • 24specifications compared
  • 17differ
  • 7identical
  • 25known for one product only

Key differences

The APC SUA5000RMI5U + WBEXTWAR3YR-SP-05 has 4 kVA more output power capacity than the Vertiv GXT3-MT On-Line UPS, 1000VA (5 kVA vs 1 kVA). The APC SUA5000RMI5U + WBEXTWAR3YR-SP-05 has 3,100 W more output power than the Vertiv GXT3-MT On-Line UPS, 1000VA (4000 W vs 900 W). The APC SUA5000RMI5U + WBEXTWAR3YR-SP-05 has 31 V more input operation voltage (min) than the Vertiv GXT3-MT On-Line UPS, 1000VA (151 V vs 120 V). Input frequency: 47/63 Hz on the APC SUA5000RMI5U + WBEXTWAR3YR-SP-05, 50/60 Hz on the Vertiv GXT3-MT On-Line UPS, 1000VA. AC outlet types: C13 coupler, C19 coupler on the APC SUA5000RMI5U + WBEXTWAR3YR-SP-05, NEMA 5–15R on the Vertiv GXT3-MT On-Line UPS, 1000VA.

  • Output power capacity
    • SUA5000RMI5U + WBEXTWAR3YR-SP-05:5 kVA
    • GXT3-MT On-Line UPS, 1000VA:1 kVA
  • Output power
    • SUA5000RMI5U + WBEXTWAR3YR-SP-05:4000 W
    • GXT3-MT On-Line UPS, 1000VA:900 W
  • Input operation voltage (min)
    • SUA5000RMI5U + WBEXTWAR3YR-SP-05:151 V
    • GXT3-MT On-Line UPS, 1000VA:120 V
  • Input operation voltage (max)
    • SUA5000RMI5U + WBEXTWAR3YR-SP-05:302 V
    • GXT3-MT On-Line UPS, 1000VA:140 V
  • Input frequency
    • SUA5000RMI5U + WBEXTWAR3YR-SP-05:47/63 Hz
    • GXT3-MT On-Line UPS, 1000VA:50/60 Hz
  • Output operation voltage (min)
    • SUA5000RMI5U + WBEXTWAR3YR-SP-05:230 V
    • GXT3-MT On-Line UPS, 1000VA:110 V
  • Output operation voltage (max)
    • SUA5000RMI5U + WBEXTWAR3YR-SP-05:230 V
    • GXT3-MT On-Line UPS, 1000VA:127 V
  • Noise level
    • SUA5000RMI5U + WBEXTWAR3YR-SP-05:53 dB
    • GXT3-MT On-Line UPS, 1000VA:43 dB

Side by side

Differences highlightedShow differences only (on)
Comparison of SUA5000RMI5U + WBEXTWAR3YR-SP-05, GXT3-MT On-Line UPS, 1000VA
49 specifications
Features8 differ
UPS topologyKnown for oneLine-InteractiveUnknown — not stated by the source
Output power capacityDiffers5 kVA1 kVA
Output powerDiffers4000 W900 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs151 V120 V
Input operation voltage (max)Differs302 V140 V
Input frequencyDiffers47/63 Hz50/60 Hz
Output operation voltage (min)Differs230 V110 V
Output operation voltage (max)Differs230 V127 V
Output frequency regulationKnown for one47 - 63 HzUnknown — not stated by the source
Surge energy ratingKnown for one480 JUnknown — not stated by the source
EfficiencyKnown for one96%Unknown — not stated by the source
Noise levelDiffers53 dB43 dB
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for oneUnknown — not stated by the source8.3 A
Power factorKnown for oneUnknown — not stated by the source0.9
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Ports & interfaces2 differ
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5–15R
AC outlets quantityDiffers14 AC outlet(s)6 AC outlet(s)
Number of output IEC jumpersKnown for one4Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Battery1 differ
Typical backup time at full loadDiffers9.4 min5 min
Typical backup time at half loadKnown for one26.7 minUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmountTower
Rack capacityKnown for one5UUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Differs-15 - 45 °C-15 - 40 °C
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneC-tick, CE, EN 50091-1, EN 50091-2, GOST, GS Mark, VDEUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers483 mm430 mm
DepthDiffers660 mm497 mm
HeightDiffers222 mm85 mm
WeightDiffers97.7 kg16.8 kg
Packaging dataidentical
Package widthKnown for one610 mmUnknown — not stated by the source
Package depthKnown for one762 mmUnknown — not stated by the source
Package heightKnown for one635 mmUnknown — not stated by the source
Package weightKnown for one106.8 kgUnknown — not stated by the source
Other featuresidentical
Number of phasesKnown for oneUnknown — not stated by the source1

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.