Product comparison · 2 uninterruptible power supplies (upss)

APC SUA2200XLI + WBEXTWAR3YR-SP-04 vs CyberPower PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA

Add a product
  • 33specifications compared
  • 22differ
  • 11identical
  • 26known for one product only

Key differences

The APC SUA2200XLI + WBEXTWAR3YR-SP-04 has 1.45 kVA more output power capacity than the CyberPower PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA (2.2 kVA vs 0.75 kVA). The APC SUA2200XLI + WBEXTWAR3YR-SP-04 has 1,305 W more output power than the CyberPower PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA (1980 W vs 675 W). The APC SUA2200XLI + WBEXTWAR3YR-SP-04 has 80 V more input operation voltage (min) than the CyberPower PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA (230 V vs 150 V). Waveform: Sine on the APC SUA2200XLI + WBEXTWAR3YR-SP-04, Pure sine on the CyberPower PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA. AC outlet types: C13 coupler, C19 coupler on the APC SUA2200XLI + WBEXTWAR3YR-SP-04, C13 coupler on the CyberPower PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA.

  • Output power capacity
    • SUA2200XLI + WBEXTWAR3YR-SP-04:2.2 kVA
    • PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:0.75 kVA
  • Output power
    • SUA2200XLI + WBEXTWAR3YR-SP-04:1980 W
    • PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:675 W
  • Waveform
    • SUA2200XLI + WBEXTWAR3YR-SP-04:Sine
    • PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:Pure sine
  • Input operation voltage (min)
    • SUA2200XLI + WBEXTWAR3YR-SP-04:230 V
    • PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:150 V
  • Input operation voltage (max)
    • SUA2200XLI + WBEXTWAR3YR-SP-04:230 V
    • PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:301 V
  • Surge energy rating
    • SUA2200XLI + WBEXTWAR3YR-SP-04:480 J
    • PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:405 J
  • AC outlet types
    • SUA2200XLI + WBEXTWAR3YR-SP-04:C13 coupler, C19 coupler
    • PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:C13 coupler
  • AC outlets quantity
    • SUA2200XLI + WBEXTWAR3YR-SP-04:11 AC outlet(s)
    • PR750ELCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:6 AC outlet(s)

Side by side

Differences highlightedShow differences only (off)
Comparison of SUA2200XLI + WBEXTWAR3YR-SP-04, PR750ELCD
59 specifications
Features6 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacityDiffers2.2 kVA0.75 kVA
Output powerDiffers1980 W675 W
WaveformDiffersSinePure sine
Input operation voltage (min)Differs230 V150 V
Input operation voltage (max)Differs230 V301 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)230 V230 V
Output operation voltage (max)230 V230 V
Maximum currentKnown for oneUnknown — not stated by the source10 A
Surge energy ratingDiffers480 J405 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Power factorKnown for oneUnknown — not stated by the source0.9
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm(s)YesYes
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Fault, Low battery alarm, Overload alarm
Output frequency regulationKnown for one47/63 HzUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Noise levelKnown for one53 dBUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
AC outlets quantityDiffers11 AC outlet(s)6 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Battery3 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Typical backup time at full loadDiffers6.7 min2.5 min
Typical backup time at half loadDiffers24.1 min10.5 min
Battery recharge timeDiffers3 h8 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Design2 differ
Form factorDiffersRackmount/TowerTower
Product colourBlackBlack
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsDiffersYesError, Operation
Rack capacityKnown for one5UUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceUSB cable
Certificates1 differ
CertificationDiffersC-tick, CE, EN 50091-1, EN 50091-2, GOST, VDECE, EAC, RCM, RoHS
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers221 mm349 mm
DepthDiffers495 mm138 mm
HeightDiffers444 mm162 mm
WeightDiffers55 kg12.3 kg
Packaging data4 differ
Package widthDiffers600 mm272 mm
Package depthDiffers780 mm486 mm
Package heightDiffers530 mm283 mm
Package weightDiffers80 kg13.3 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source8504408590
Country of originKnown for oneUnknown — not stated by the sourceChina
Other featuresidentical
Overload protectionKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons