Product comparison · 2 uninterruptible power supplies (upss)

APC SUA1500I - KIT vs APC SUA2200I Kit

Add a product
  • 27specifications compared
  • 11differ
  • 16identical
  • 7known for one product only

Key differences

The APC SUA2200I Kit has 0.7 kVA more output power capacity than the APC SUA1500I - KIT (2.2 kVA vs 1.5 kVA). The APC SUA2200I Kit has 1,000 W more output power than the APC SUA1500I - KIT (1980 W vs 980 W). The APC SUA1500I - KIT has 160 J more surge energy rating than the APC SUA2200I Kit (480 J vs 320 J). Output connections: 8 x IEC 320 C13 on the APC SUA1500I - KIT, 8 x IEC 320 C13 1 x IEC 320 C19 on the APC SUA2200I Kit. Dimensions (WxDxH): 170 x 439.4 x 216 mm on the APC SUA1500I - KIT, 196 x 546 x 432 mm on the APC SUA2200I Kit.

  • Output power capacity
    • SUA1500I - KIT:1.5 kVA
    • SUA2200I Kit:2.2 kVA
  • Output power
    • SUA1500I - KIT:980 W
    • SUA2200I Kit:1980 W
  • Surge energy rating
    • SUA1500I - KIT:480 J
    • SUA2200I Kit:320 J
  • Number of output IEC jumpers
    • SUA1500I - KIT:2
    • SUA2200I Kit:3
  • Typical backup time at half load
    • SUA1500I - KIT:23.9 min
    • SUA2200I Kit:24.1 min
  • Weight
    • SUA1500I - KIT:24.1 kg
    • SUA2200I Kit:50.9 kg
  • Package weight
    • SUA1500I - KIT:27 kg
    • SUA2200I Kit:60.9 kg
  • Dimensions (WxDxH)
    • SUA1500I - KIT:170 x 439.4 x 216 mm
    • SUA2200I Kit:196 x 546 x 432 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of SUA1500I - KIT, SUA2200I Kit
34 specifications
Features3 differ
Output power capacityDiffers1.5 kVA2.2 kVA
Output powerDiffers980 W1980 W
Surge energy ratingDiffers480 J320 J
Noise level45 dB45 dB
Audible alarm(s)YesYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
Number of output IEC jumpersDiffers23
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Battery1 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Typical backup time at full load6.7 min6.7 min
Typical backup time at half loadDiffers23.9 min24.1 min
Battery recharge time3 h3 h
Designidentical
Product colourBlackBlack
Cable lengthKnown for one1.83 mUnknown — not stated by the source
LED indicatorsYesYes
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Certificates1 differ
CertificationDiffersC-tick, CE, EN 50091-1, EN 50091-2, GOST, VDEC-tick, CE, EN 50091-1, EN 50091-2, GOST, PCBC, VDE
Weight & dimensions1 differ
WeightDiffers24.1 kg50.9 kg
Packaging data1 differ
Package weightDiffers27 kg60.9 kg
Other features3 differ
Output connectionsDiffers8 x IEC 320 C138 x IEC 320 C13 1 x IEC 320 C19
Dimensions (WxDxH)Differs170 x 439.4 x 216 mm196 x 546 x 432 mm
FilteringYesYes
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltage230 V230 V
Output voltage note220, 230, 240220, 230, 240
Package dimensions (WxDxH)Differs330 x 584 x 381 mm381 x 762 x 559 mm
Mac compatibilityKnown for oneUnknown — not stated by the sourceYes
I/O portsKnown for oneUnknown — not stated by the source1 x DB-9 RS-232 1 x USB 1 x SmartSlot

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.