Product comparison · 2 uninterruptible power supplies (upss)

APC SU1400R2BX120 uninterruptible power supply (UPS) 1.4 kVA vs Vertiv Liebert GXT3 6000

Add a product
  • 14specifications compared
  • 8differ
  • 6identical
  • 23known for one product only

Key differences

  • Output power capacity
    • SU1400R2BX120 uninterruptible power supply (UPS) 1.4 kVA:1.4 kVA
    • Liebert GXT3 6000:6 kVA
  • Output power
    • SU1400R2BX120 uninterruptible power supply (UPS) 1.4 kVA:950 W
    • Liebert GXT3 6000:4800 W
  • Noise level
    • SU1400R2BX120 uninterruptible power supply (UPS) 1.4 kVA:46 dB
    • Liebert GXT3 6000:55 dB
  • Storage temperature (T-T)
    • SU1400R2BX120 uninterruptible power supply (UPS) 1.4 kVA:-15 - 45 °C
    • Liebert GXT3 6000:-15 - 50 °C
  • Operating relative humidity (H-H)
    • SU1400R2BX120 uninterruptible power supply (UPS) 1.4 kVA:0 - 95%
    • Liebert GXT3 6000:0 - 90%
  • Operating altitude
    • SU1400R2BX120 uninterruptible power supply (UPS) 1.4 kVA:0 - 3000 m
    • Liebert GXT3 6000:0 - 1000 m
  • Nominal input voltage
    • SU1400R2BX120 uninterruptible power supply (UPS) 1.4 kVA:120 V
    • Liebert GXT3 6000:220-240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of SU1400R2BX120, Liebert GXT3 6000
37 specifications
Features3 differ
Output power capacityDiffers1.4 kVA6 kVA
Output powerDiffers950 W4800 W
Input frequency50/60 Hz50/60 Hz
Surge energy ratingKnown for one480 JUnknown — not stated by the source
Emergency Power Off (EPO)YesYes
Noise levelDiffers46 dB55 dB
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Batteryidentical
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery recharge time3 h3 h
Number of battery cellsKnown for oneUnknown — not stated by the source20
Designidentical
Product colourBlackBlack
Cable lengthKnown for one1.83 mUnknown — not stated by the source
Form factorKnown for oneUnknown — not stated by the sourceRackmount/Tower
CompatibilityKnown for oneUnknown — not stated by the sourcePD2-CE10HDWRDMBS
Operational conditions3 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-15 - 45 °C-15 - 50 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeDiffers0 - 3000 m0 - 1000 m
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCSA,FCC Part 15 Class A,UL 1778- IEC/EN/AS 62040-2 - EN61000-4-2 - EN61000-4-3 - EN61000-4-4 - EN61000-4-5 - CE
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensionsidentical
WeightKnown for one28.6 kgUnknown — not stated by the source
WidthKnown for oneUnknown — not stated by the source574 mm
DepthKnown for oneUnknown — not stated by the source430 mm
HeightKnown for oneUnknown — not stated by the source217 mm
Packaging dataidentical
Package weightKnown for one31.9 kgUnknown — not stated by the source
Other features1 differ
Battery typeKnown for oneRBC24Unknown — not stated by the source
InterfaceKnown for oneDB-9 RS-232, SmartSlotUnknown — not stated by the source
Output connectionsKnown for one6x NEMA 5-15RUnknown — not stated by the source
Input connection typeKnown for oneNEMA 5-15PUnknown — not stated by the source
Dimensions (WxDxH)Known for one483 x 457 x 89 mmUnknown — not stated by the source
Nominal input voltageDiffers120 V220-240 V
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Package dimensions (WxDxH)Known for oneUnknown — not stated by the source745 x 530 x 516 mm
Ports & interfacesidentical
Number of output IEC jumpersKnown for oneUnknown — not stated by the source8
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceIEC62040-1:2008

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.