The CyberPower BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s) has 50 A more maximum current than the APC STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA (60 A vs 10 A). The CyberPower BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s) has 328 mm more width than the APC STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA (433 mm vs 105 mm). The CyberPower BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s) has 70 mm more depth than the APC STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA (430 mm vs 360 mm). AC outlets quantity: 6 AC outlet(s) on the APC STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA, 10 AC outlet(s) on the CyberPower BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s). Form factor: Tower on the APC STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA, Rackmount on the CyberPower BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s).

  • Maximum current
    • STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA:10 A
    • BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s):60 A
  • AC outlets quantity
    • STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA:6 AC outlet(s)
    • BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s):10 AC outlet(s)
  • Form factor
    • STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA:Tower
    • BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s):Rackmount
  • Storage relative humidity (H-H)
    • STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA:0 - 90%
    • BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s):0 - 95%
  • Operating altitude
    • STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA:0 - 2952 m
    • BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s):0 - 3000 m
  • Non-operating altitude
    • STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA:0 - 14763 m
    • BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s):0 - 15000 m
  • Width
    • STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA:105 mm
    • BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s):433 mm
  • Depth
    • STAYTION1200BI uninterruptible power supply (UPS) 1.2 kVA:360 mm
    • BP36V60ART2U uninterruptible power supply (UPS) 10 AC outlet(s):430 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of STAYTION1200BI, BP36V60ART2U
44 specifications
Features1 differ
Output power capacityKnown for one1.2 kVAUnknown — not stated by the source
Output powerKnown for one420 WUnknown — not stated by the source
Input operation voltage (min)Known for one100 VUnknown — not stated by the source
Input operation voltage (max)Known for one260 VUnknown — not stated by the source
Input frequencyKnown for one60 HzUnknown — not stated by the source
Maximum currentDiffers10 A60 A
Surge energy ratingKnown for one75 JUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneFax, ModemUnknown — not stated by the source
Power protection featuresKnown for oneOverload, Short circuitUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Output operation voltage (min)Known for oneUnknown — not stated by the source36 V
Ports & interfaces1 differ
AC outlets quantityDiffers6 AC outlet(s)10 AC outlet(s)
Batteryidentical
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Number of battery cellsKnown for oneUnknown — not stated by the source6
Battery recharge timeKnown for oneUnknown — not stated by the source5 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorDiffersTowerRackmount
Cable lengthKnown for one1.28 mUnknown — not stated by the source
LED indicatorsKnown for onePower, StatusUnknown — not stated by the source
Housing materialKnown for oneUnknown — not stated by the sourceSteel
Rack capacityKnown for oneUnknown — not stated by the source2U
Operational conditions3 differ
Storage relative humidity (H-H)Differs0 - 90%0 - 95%
Operating altitudeDiffers0 - 2952 m0 - 3000 m
Non-operating altitudeDiffers0 - 14763 m0 - 15000 m
Weight & dimensions4 differ
WidthDiffers105 mm433 mm
DepthDiffers360 mm430 mm
HeightDiffers180 mm88 mm
WeightDiffers9.69 kg22.9 kg
Packaging data1 differ
Package weightDiffers9.99 kg29.6 kg
Other features1 differ
Input connection typeKnown for oneNBR 14136Unknown — not stated by the source
Nominal input voltageKnown for one115-220 VUnknown — not stated by the source
Nominal output voltageKnown for one115 VUnknown — not stated by the source
Overload protectionKnown for oneYesUnknown — not stated by the source
Package dimensions (WxDxH)Differs108 x 401 x 181 mm550 x 590 x 240 mm
Battery typeKnown for oneUnknown — not stated by the source12V/9AH
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationKnown for oneUnknown — not stated by the sourceUL1778, CSA C22.2 NO.107.3-05, FCC DOC A

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.