Product comparison · 2 uninterruptible power supplies (upss)

APC SRV3KIL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA vs CyberPower OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA

Add a product
  • 31specifications compared
  • 20differ
  • 11identical
  • 37known for one product only

Key differences

  • UPS topology
    • SRV3KIL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Double-conversion (Online)
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:Line-Interactive
  • Output power capacity
    • SRV3KIL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:0.75 kVA
  • Output power
    • SRV3KIL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2400 W
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:525 W
  • Waveform
    • SRV3KIL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Pure sine
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:Sine
  • Input operation voltage (min)
    • SRV3KIL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:160 V
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:78 V
  • Input operation voltage (max)
    • SRV3KIL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:280 V
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:142 V
  • Input frequency
    • SRV3KIL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:40/70 Hz
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:47/63 Hz
  • Output operation voltage (min)
    • SRV3KIL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:220 V
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:120 V

Side by side

Differences highlightedShow differences only (off)
Comparison of SRV3KIL, OR750PFCLCD
68 specifications
Features11 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers3 kVA0.75 kVA
Output powerDiffers2400 W525 W
WaveformDiffersPure sineSine
Input operation voltage (min)Differs160 V78 V
Input operation voltage (max)Differs280 V142 V
Input frequencyDiffers40/70 Hz47/63 Hz
Output operation voltage (min)Differs220 V120 V
Output operation voltage (max)Differs240 V120 V
Output frequency50/60 Hz50/60 Hz
Surge energy ratingDiffers600 J1030 J
Crest factorKnown for one3:1Unknown — not stated by the source
ECO modeKnown for oneYesUnknown — not stated by the source
Audible alarm(s)YesYes
Audible alarm modesDiffersAlarm when on battery, Low battery alarm, Overload alarmLow battery alarm, Overload alarm
Auto-restartKnown for oneYesUnknown — not stated by the source
Output voltage regulationKnown for oneUnknown — not stated by the source5%
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Output power factorKnown for oneUnknown — not stated by the source0.7
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesKnown for oneC13 coupler, C19 couplerUnknown — not stated by the source
Power plugDiffersC14 couplerNEMA 5-15P
AC outlets quantityDiffers7 AC outlet(s)6 AC outlet(s)
USB portYesYes
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Serial interfaceYesYes
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Serial ports quantity11
SmartSlotKnown for oneYesUnknown — not stated by the source
Batteryidentical
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Automatic battery testKnown for oneYesUnknown — not stated by the source
Battery weightKnown for one29 kgUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of battery cellsKnown for oneUnknown — not stated by the source2
Typical backup time at full loadKnown for oneUnknown — not stated by the source5.5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source15 min
Battery recharge timeKnown for oneUnknown — not stated by the source8 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRB1270X2D
Design1 differ
Form factorDiffersTowerMini Tower
Product colourBlackBlack
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsYesYes
Cable lengthKnown for oneUnknown — not stated by the source1.8 m
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-20 - 50 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 14763.6 mUnknown — not stated by the source
Packaging content1 differ
Cables includedDiffersUSB cableInput power cable
ManualKnown for oneYesUnknown — not stated by the source
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneCE, IEC 62040-1-1, IEC 62040-1-2 REACHUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers425 mm162.5 mm
DepthDiffers425 mm350.5 mm
HeightDiffers336 mm137 mm
WeightDiffers45.9 kg10.2 kg
Battery widthKnown for one32.5 cmUnknown — not stated by the source
Battery depthKnown for one56.5 cmUnknown — not stated by the source
Battery heightKnown for one46.5 cmUnknown — not stated by the source
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other featuresidentical
Input connection typeKnown for one1 x IEC 320 C19 & 6 x IEC 320 C1Unknown — not stated by the source
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL1778 4th cUL 107.3 FCC DOC Class B

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.