Product comparison · 2 uninterruptible power supplies (upss)

APC SRV10KRILRK uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA vs CyberPower OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA

Add a product
  • 27specifications compared
  • 16differ
  • 11identical
  • 40known for one product only

Key differences

  • UPS topology
    • SRV10KRILRK uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:Double-conversion (Online)
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:Line-Interactive
  • Output power capacity
    • SRV10KRILRK uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:10 kVA
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:0.75 kVA
  • Output power
    • SRV10KRILRK uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:10000 W
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:525 W
  • Waveform
    • SRV10KRILRK uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:Pure sine
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:Sine
  • Input operation voltage (min)
    • SRV10KRILRK uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:110 V
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:78 V
  • Input operation voltage (max)
    • SRV10KRILRK uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:300 V
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:142 V
  • Input frequency
    • SRV10KRILRK uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:40/70 Hz
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:47/63 Hz
  • Output operation voltage (min)
    • SRV10KRILRK uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:220 V
    • OR750PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:120 V

Side by side

Differences highlightedShow differences only (off)
Comparison of SRV10KRILRK, OR750PFCLCD
67 specifications
Features10 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers10 kVA0.75 kVA
Output powerDiffers10000 W525 W
WaveformDiffersPure sineSine
Input operation voltage (min)Differs110 V78 V
Input operation voltage (max)Differs300 V142 V
Input frequencyDiffers40/70 Hz47/63 Hz
Output operation voltage (min)Differs220 V120 V
Output operation voltage (max)Differs240 V120 V
Output frequency50/60 Hz50/60 Hz
Surge energy ratingDiffers600 J1030 J
Crest factorKnown for one3:1Unknown — not stated by the source
ECO modeKnown for oneYesUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Audible alarm(s)YesYes
Audible alarm modesLow battery alarm, Overload alarmLow battery alarm, Overload alarm
Auto-restartKnown for oneYesUnknown — not stated by the source
Output voltage regulationKnown for oneUnknown — not stated by the source5%
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Output power factorKnown for oneUnknown — not stated by the source0.7
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlet typesKnown for oneHard Wire 3-wire (1PH + N + G)Unknown — not stated by the source
USB portYesYes
Serial interfaceYesYes
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
SmartSlotKnown for oneYesUnknown — not stated by the source
SmartConnect portKnown for oneNoUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15P
AC outlets quantityKnown for oneUnknown — not stated by the source6 AC outlet(s)
Serial ports quantityKnown for oneUnknown — not stated by the source1
Batteryidentical
Hot-swap batteryYesYes
Automatic battery testKnown for oneYesUnknown — not stated by the source
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of battery cellsKnown for oneUnknown — not stated by the source2
Typical backup time at full loadKnown for oneUnknown — not stated by the source5.5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source15 min
Battery recharge timeKnown for oneUnknown — not stated by the source8 h
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRB1270X2D
Design1 differ
Form factorDiffersRackmountMini Tower
Product colourBlackBlack
Rack capacityKnown for one5UUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsYesYes
Cable lengthKnown for oneUnknown — not stated by the source1.8 m
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 14763 mUnknown — not stated by the source
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 45 °C
Packaging content1 differ
Cables includedDiffersUSB cableInput power cable
Management card includedKnown for oneNoUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneCE, IEC 62040-1-1, IEC 62040-1-2 REACHUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers438 mm162.5 mm
DepthDiffers615 mm350.5 mm
HeightDiffers220 mm137 mm
WeightDiffers78 kg10.2 kg
Packaging dataidentical
Package weightKnown for one79 kgUnknown — not stated by the source
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other featuresidentical
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL1778 4th cUL 107.3 FCC DOC Class B

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.