Product comparison · 2 uninterruptible power supplies (upss)

APC 5kVA and 6kVA Marine Filter Rack-Mount vs Vertiv Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA

Add a product
  • 12specifications compared
  • 11differ
  • 1identical
  • 33known for one product only

Key differences

The Vertiv Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA has 54 kVA more output power capacity than the APC 5kVA and 6kVA Marine Filter Rack-Mount (60 kVA vs 6 kVA). The Vertiv Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA has 205 V more input operation voltage (min) than the APC 5kVA and 6kVA Marine Filter Rack-Mount (305 V vs 100 V). The Vertiv Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA has 237 V more input operation voltage (max) than the APC 5kVA and 6kVA Marine Filter Rack-Mount (477 V vs 240 V). Input frequency: 45/65 Hz on the APC 5kVA and 6kVA Marine Filter Rack-Mount, 50/60 Hz on the Vertiv Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA. Form factor: Rackmount on the APC 5kVA and 6kVA Marine Filter Rack-Mount, Tower on the Vertiv Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA.

  • Output power capacity
    • 5kVA and 6kVA Marine Filter Rack-Mount:6 kVA
    • Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA:60 kVA
  • Input operation voltage (min)
    • 5kVA and 6kVA Marine Filter Rack-Mount:100 V
    • Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA:305 V
  • Input operation voltage (max)
    • 5kVA and 6kVA Marine Filter Rack-Mount:240 V
    • Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA:477 V
  • Input frequency
    • 5kVA and 6kVA Marine Filter Rack-Mount:45/65 Hz
    • Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA:50/60 Hz
  • Output operation voltage (min)
    • 5kVA and 6kVA Marine Filter Rack-Mount:200 V
    • Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA:380 V
  • Output operation voltage (max)
    • 5kVA and 6kVA Marine Filter Rack-Mount:240 V
    • Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA:415 V
  • Form factor
    • 5kVA and 6kVA Marine Filter Rack-Mount:Rackmount
    • Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA:Tower
  • Width
    • 5kVA and 6kVA Marine Filter Rack-Mount:483 mm
    • Liebert LI60601A1001A10 uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA:600 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of SRT6RMM, LI60601A1001A10
45 specifications
Features6 differ
Output power capacityDiffers6 kVA60 kVA
Input operation voltage (min)Differs100 V305 V
Input operation voltage (max)Differs240 V477 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Differs200 V380 V
Output operation voltage (max)Differs240 V415 V
UPS topologyKnown for oneUnknown — not stated by the sourceDouble-conversion (Online)
Output powerKnown for oneUnknown — not stated by the source54000 W
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source0.9
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Noise levelKnown for oneUnknown — not stated by the source58 dB
Ports & interfacesidentical
AC outlet typesKnown for oneHardwireUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmountTower
Product colourBlackBlack
Rack capacityKnown for one1UUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 55 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 75 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneRoHS, REACH, WEEEUnknown — not stated by the source
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationDiffersDNVEN/IEC/AS 62040-1, EN/IEC/AS 62040-2, VFI-SS-111
Technical detailsidentical
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers483 mm600 mm
DepthDiffers330 mm850 mm
HeightDiffers44 mm1600 mm
WeightKnown for one6.73 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one559 mmUnknown — not stated by the source
Package depthKnown for one406 mmUnknown — not stated by the source
Package heightKnown for one76 mmUnknown — not stated by the source
Package weightKnown for one8.27 kgUnknown — not stated by the source
Logistics dataidentical
Customs product code (TARIC)Known for one8543709099Unknown — not stated by the source
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one1634.475049186192Unknown — not stated by the source
Country of originKnown for onePhilippinesUnknown — not stated by the source
Other featuresidentical
MountingKnown for onefront; horizontalUnknown — not stated by the source
Output connection typeKnown for onehard wire 3-wire (H N + E) for 1 zone(s)Unknown — not stated by the source
Output voltageKnown for one200 VUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.