Product comparison · 2 uninterruptible power supplies (upss)

APC SRT3000RMXLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA vs CyberPower PR1500LCDRT2UN uninterruptible power supply (UPS) Line-Interactive 1.5 kVA

Add a product
  • 43specifications compared
  • 27differ
  • 16identical
  • 31known for one product only

Key differences

  • UPS topology
    • SRT3000RMXLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Double-conversion (Online)
    • PR1500LCDRT2UN uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Line-Interactive
  • Output power capacity
    • SRT3000RMXLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • PR1500LCDRT2UN uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
  • Output power
    • SRT3000RMXLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2700 W
    • PR1500LCDRT2UN uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1350 W
  • Input operation voltage (min)
    • SRT3000RMXLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:100 V
    • PR1500LCDRT2UN uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:109 V
  • Input operation voltage (max)
    • SRT3000RMXLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:275 V
    • PR1500LCDRT2UN uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:131 V
  • Input frequency
    • SRT3000RMXLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:40 - 70 Hz
    • PR1500LCDRT2UN uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:47/63 Hz
  • Output operation voltage (max)
    • SRT3000RMXLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
    • PR1500LCDRT2UN uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:120 V
  • Surge energy rating
    • SRT3000RMXLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:340 J
    • PR1500LCDRT2UN uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:2060 J

Side by side

Differences highlightedShow differences only (on)
Comparison of SRT3000RMXLT, PR1500LCDRT2UN
74 specifications
Features10 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers3 kVA1.5 kVA
Output powerDiffers2700 W1350 W
Input operation voltage (min)Differs100 V109 V
Input operation voltage (max)Differs275 V131 V
Input frequencyDiffers40 - 70 Hz47/63 Hz
Output operation voltage (max)Differs240 V120 V
Surge energy ratingDiffers340 J2060 J
Response timeKnown for oneUnknown — not stated by the source4 ms
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Noise levelDiffers55 dB35 dB
Power protection featuresDiffersOverloadShort circuit
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Low battery alarm, Overload alarm
Output operation voltage (min)Known for one208 VUnknown — not stated by the source
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
EfficiencyKnown for one92.7%Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one2%Unknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Ports & interfaces4 differ
AC outlet typesDiffersNEMA L6-20R, NEMA L6-30RNEMA 5–15R
Power plugDiffersNEMA L6-20PNEMA 5-15P
AC outlets quantityDiffers3 AC outlet(s)8 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Ethernet LAN (RJ-45) portsDiffers32
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
USB 2.0 ports quantityKnown for one3Unknown — not stated by the source
Battery3 differ
Battery capacityDiffers497 Ah7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source4
Typical backup time at half loadDiffers9 min11 min
Battery recharge timeDiffers3 h6 h
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Design2 differ
Cable lengthDiffers1.82 m3.04 m
LED indicatorsDiffersBattery replacementPower
Housing materialKnown for oneSteelUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditionsidentical
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 45 °C
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Cables includedKnown for oneUnknown — not stated by the sourceSerial, USB cable
ManualKnown for oneUnknown — not stated by the sourceYes
Quick installation guideKnown for oneYesUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
Weight & dimensions4 differ
WidthDiffers432 mm438.1 mm
DepthDiffers635 mm400.1 mm
HeightDiffers85 mm88.9 mm
WeightDiffers31.3 kg25.5 kg
Packaging data4 differ
Software CDKnown for oneUnknown — not stated by the sourceYes
Warranty cardKnown for oneUnknown — not stated by the sourceYes
Package widthDiffers599 mm558.8 mm
Package depthDiffers871 mm520.7 mm
Package heightDiffers246 mm248.9 mm
Package weightDiffers39.9 kg27.8 kg
Logistics dataidentical
Products per palletKnown for one6 pc(s)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.