Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS On-Line, 2200VA, Rackmount 2U vs CyberPower OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA

Add a product
  • 38specifications compared
  • 25differ
  • 13identical
  • 36known for one product only

Key differences

  • Output power capacity
    • Smart-UPS On-Line, 2200VA, Rackmount 2U:2.2 kVA
    • OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:8 kVA
  • Output power
    • Smart-UPS On-Line, 2200VA, Rackmount 2U:1980 W
    • OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:8000 W
  • Input operation voltage (min)
    • Smart-UPS On-Line, 2200VA, Rackmount 2U:50 V
    • OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:200 V
  • Input operation voltage (max)
    • Smart-UPS On-Line, 2200VA, Rackmount 2U:230 V
    • OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:240 V
  • Input frequency
    • Smart-UPS On-Line, 2200VA, Rackmount 2U:40/70 Hz
    • OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:50/60 Hz
  • Output operation voltage (max)
    • Smart-UPS On-Line, 2200VA, Rackmount 2U:230 V
    • OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:245 V
  • Surge energy rating
    • Smart-UPS On-Line, 2200VA, Rackmount 2U:432 J
    • OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:2430 J
  • Heat dissipation
    • Smart-UPS On-Line, 2200VA, Rackmount 2U:317 BTU/h
    • OL8KRTHD uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:1589 BTU/h

Side by side

Differences highlightedShow differences only (on)
Comparison of SRT2200UXI-LI, OL8KRTHD
74 specifications
Features9 differ
Output power capacityDiffers2.2 kVA8 kVA
Output powerDiffers1980 W8000 W
Input operation voltage (min)Differs50 V200 V
Input operation voltage (max)Differs230 V240 V
Input frequencyDiffers40/70 Hz50/60 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source196 V
Output operation voltage (max)Differs230 V245 V
Output frequency regulationKnown for oneUnknown — not stated by the source1 Hz
Output voltage regulationKnown for oneUnknown — not stated by the source2%
Maximum currentKnown for oneUnknown — not stated by the source60 A
Surge energy ratingDiffers432 J2430 J
Heat dissipationDiffers317 BTU/h1589 BTU/h
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
EfficiencyKnown for oneUnknown — not stated by the source98%
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Noise levelDiffers50 dB66 dB
Crest factorKnown for one3:1Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one2%Unknown — not stated by the source
Ports & interfaces3 differ
AC outlet typesDiffersC13 coupler, C19 couplerNEMA L6-20R, NEMA L6-30R
Power plugKnown for oneUnknown — not stated by the sourceNEMA L6-30P
AC outlets quantityDiffers8 AC outlet(s)6 AC outlet(s)
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-B
Serial interface typeDiffersRJ-45RS-232
RS-232 portsKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
SmartSlotKnown for oneYesUnknown — not stated by the source
Batteryidentical
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source16
Typical backup time at full loadKnown for oneUnknown — not stated by the source3.8 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source11 min
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Automatic battery testKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceBP192VL2U01
Design1 differ
Rack capacityDiffers2U4U
Control typeKnown for oneUnknown — not stated by the sourceButtons
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsKnown for oneUnknown — not stated by the sourcePower
Cable lengthKnown for one1.8 mUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions3 differ
Storage temperature (T-T)Differs-20 - 50 °C-20 - 45 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Non-operating altitudeDiffers0 - 15240 m0 - 15239 m
Certificates1 differ
Compliance certificatesDiffersCE, EAC, REACH, RoHSUL, cUL, CSA, Federal Communications Commission (FCC), RoHS
Weight & dimensions4 differ
WidthDiffers85 mm433 mm
DepthDiffers508 mm720 mm
HeightDiffers432 mm173 mm
WeightDiffers22 kg71.2 kg
Packaging data4 differ
Package widthDiffers749 mm890 mm
Package depthDiffers594 mm590 mm
Package heightDiffers246 mm452.1 mm
Package weightDiffers29.6 kg90.7 kg
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one3558.01Unknown — not stated by the source
Warranty periodKnown for one5 year(s)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.