Product comparison · 2 uninterruptible power supplies (upss)

APC SMX750I + War 3Y vs CyberPower VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA

Add a product
  • 26specifications compared
  • 11differ
  • 15identical
  • 38known for one product only

Key differences

The CyberPower VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA has 0.25 kVA more output power capacity than the APC SMX750I + War 3Y (1 kVA vs 0.75 kVA). The APC SMX750I + War 3Y has 50 W more output power than the CyberPower VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA (600 W vs 550 W). The APC SMX750I + War 3Y has 13.2 min more typical backup time at full load than the CyberPower VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA (14.2 min vs 1 min). Input frequency: 47/63 Hz on the APC SMX750I + War 3Y, 50/60 Hz on the CyberPower VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA. AC outlets quantity: 8 AC outlet(s) on the APC SMX750I + War 3Y, 3 AC outlet(s) on the CyberPower VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA.

  • Output power capacity
    • SMX750I + War 3Y:0.75 kVA
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:1 kVA
  • Output power
    • SMX750I + War 3Y:600 W
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:550 W
  • Input frequency
    • SMX750I + War 3Y:47/63 Hz
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:50/60 Hz
  • AC outlets quantity
    • SMX750I + War 3Y:8 AC outlet(s)
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:3 AC outlet(s)
  • Typical backup time at full load
    • SMX750I + War 3Y:14.2 min
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:1 min
  • Typical backup time at half load
    • SMX750I + War 3Y:37.8 min
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:6.5 min
  • Form factor
    • SMX750I + War 3Y:Rackmount/Tower
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:Tower
  • Width
    • SMX750I + War 3Y:432 mm
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:100 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of SMX750I + War 3Y, VALUE1000EILCD
64 specifications
Features3 differ
UPS topologyKnown for oneLine-InteractiveUnknown — not stated by the source
Output power capacityDiffers0.75 kVA1 kVA
Output powerDiffers600 W550 W
Input operation voltage (min)Known for one151 VUnknown — not stated by the source
Input operation voltage (max)Known for one302 VUnknown — not stated by the source
Input frequencyDiffers47/63 Hz50/60 Hz
Surge energy ratingKnown for one645 JUnknown — not stated by the source
EfficiencyKnown for one97.7%Unknown — not stated by the source
Noise levelKnown for one40 dBUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceFax, Modem, Network, Telephone
Ports & interfaces1 differ
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
AC outlets quantityDiffers8 AC outlet(s)3 AC outlet(s)
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Battery2 differ
Typical backup time at full loadDiffers14.2 min1 min
Typical backup time at half loadDiffers37.8 min6.5 min
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source8.5 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Design1 differ
Form factorDiffersRackmount/TowerTower
Rack capacityKnown for one2UUnknown — not stated by the source
Cable lengthKnown for one1.83 mUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneC-tick, CE, EN 50091-1, EN 50091-2, VDEUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm100 mm
DepthDiffers490 mm300 mm
HeightDiffers89 mm140 mm
WeightDiffers22.1 kg5.6 kg
Packaging dataidentical
Package widthKnown for one589 mmUnknown — not stated by the source
Package depthKnown for one620 mmUnknown — not stated by the source
Package heightKnown for one246 mmUnknown — not stated by the source
Package weightKnown for one26.5 kgUnknown — not stated by the source
Bundled softwareKnown for oneUnknown — not stated by the sourcePowerPanel
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other featuresidentical
Number of phasesKnown for one1Unknown — not stated by the source
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Communication options, slotKnown for oneSmartSlotUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.