Product comparison · 2 uninterruptible power supplies (upss)

APC SMX750 uninterruptible power supply (UPS) 0.75 kVA vs Vertiv Liebert GXT3 On-Line RT 6000VA

Add a product
  • 20specifications compared
  • 15differ
  • 5identical
  • 25known for one product only

Key differences

  • Output power capacity
    • SMX750 uninterruptible power supply (UPS) 0.75 kVA:0.75 kVA
    • Liebert GXT3 On-Line RT 6000VA:6 kVA
  • Output power
    • SMX750 uninterruptible power supply (UPS) 0.75 kVA:600 W
    • Liebert GXT3 On-Line RT 6000VA:4800 W
  • Input operation voltage (min)
    • SMX750 uninterruptible power supply (UPS) 0.75 kVA:75 V
    • Liebert GXT3 On-Line RT 6000VA:120 V
  • Input operation voltage (max)
    • SMX750 uninterruptible power supply (UPS) 0.75 kVA:154 V
    • Liebert GXT3 On-Line RT 6000VA:208 V
  • Input frequency
    • SMX750 uninterruptible power supply (UPS) 0.75 kVA:50/60 Hz
    • Liebert GXT3 On-Line RT 6000VA:40/70 Hz
  • Output operation voltage (min)
    • SMX750 uninterruptible power supply (UPS) 0.75 kVA:120 V
    • Liebert GXT3 On-Line RT 6000VA:100 V
  • Output operation voltage (max)
    • SMX750 uninterruptible power supply (UPS) 0.75 kVA:120 V
    • Liebert GXT3 On-Line RT 6000VA:127 V
  • Output voltage Total Harmonic Distortion (THD)
    • SMX750 uninterruptible power supply (UPS) 0.75 kVA:5%
    • Liebert GXT3 On-Line RT 6000VA:2%

Side by side

Differences highlightedShow differences only (on)
Comparison of SMX750, Liebert GXT3 On-Line RT 6000VA
45 specifications
Features9 differ
Output power capacityDiffers0.75 kVA6 kVA
Output powerDiffers600 W4800 W
Input operation voltage (min)Differs75 V120 V
Input operation voltage (max)Differs154 V208 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output operation voltage (min)Differs120 V100 V
Output operation voltage (max)Differs120 V127 V
Maximum currentKnown for one12 AUnknown — not stated by the source
Surge energy ratingKnown for one645 JUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Differs5%2%
Noise levelDiffers40 dB55 dB
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneNEMA 5–15RUnknown — not stated by the source
AC outlets quantityKnown for one8 AC outlet(s)Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceTerminal
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Design1 differ
Rack capacityDiffers2U4U
Cable lengthKnown for one2.44 mUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Storage temperature (T-T)Differs-15 - 45 °C-15 - 50 °C
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for onecUL Listed,UL 1778Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers89 mm430 mm
DepthDiffers490 mm662 mm
HeightDiffers432 mm173 mm
WeightDiffers22.1 kg25.5 kg
Packaging dataidentical
Package weightKnown for one26.5 kgUnknown — not stated by the source
Other featuresidentical
Battery typeKnown for oneAPCRBC116Unknown — not stated by the source
InterfaceKnown for oneSmartSlot,USBUnknown — not stated by the source
Nominal input voltageKnown for one120 VUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Package dimensions (WxDxH)Known for one246 x 620 x 589 mmUnknown — not stated by the source
Number of phasesKnown for oneUnknown — not stated by the source1
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL 1778, c-UL

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons