Product comparison · 2 uninterruptible power supplies (upss)

APC SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA vs CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA

Add a product
  • 33specifications compared
  • 20differ
  • 13identical
  • 30known for one product only

Key differences

The APC SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA has 0.5 kVA more output power capacity than the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA (1.5 kVA vs 1 kVA). The APC SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA has 400 W more output power than the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA (1200 W vs 800 W). The APC SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA has 182 V more input operation voltage (max) than the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA (302 V vs 120 V). AC outlet types: C13 coupler on the APC SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, NEMA 5–15R on the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA. Power plug: C14 coupler on the APC SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, NEMA 5-15P on the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA.

  • Output power capacity
    • SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:1 kVA
  • Output power
    • SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1200 W
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:800 W
  • Input operation voltage (max)
    • SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:302 V
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:120 V
  • Surge energy rating
    • SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:645 J
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:1030 J
  • AC outlet types
    • SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:C13 coupler
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:NEMA 5–15R
  • Power plug
    • SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:C14 coupler
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:NEMA 5-15P
  • AC outlets quantity
    • SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:8 AC outlet(s)
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:7 AC outlet(s)
  • Battery recharge time
    • SMX1500RMI2U-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:3 h
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:6 h

Side by side

Differences highlightedShow differences only (on)
Comparison of SMX1500RMI2U-BNDL, PR1000LCDRT1U
63 specifications
Features4 differ
Output power capacityDiffers1.5 kVA1 kVA
Output powerDiffers1200 W800 W
Input operation voltage (min)Known for one151 VUnknown — not stated by the source
Input operation voltage (max)Differs302 V120 V
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for one10 AUnknown — not stated by the source
Surge energy ratingDiffers645 J1030 J
EfficiencyKnown for one98.5%Unknown — not stated by the source
Noise levelKnown for one40 dBUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Output operation voltage (max)Known for oneUnknown — not stated by the source120 V
Output frequencyKnown for oneUnknown — not stated by the source60 Hz
Power factorKnown for oneUnknown — not stated by the source0.8
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlet typesDiffersC13 couplerNEMA 5–15R
Power plugDiffersC14 couplerNEMA 5-15P
AC outlets quantityDiffers8 AC outlet(s)7 AC outlet(s)
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
Battery1 differ
Battery recharge timeDiffers3 h6 h
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Number of batteries supportedKnown for oneUnknown — not stated by the source4
Typical backup time at full loadKnown for oneUnknown — not stated by the source3.5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source13 min
Design2 differ
Form factorDiffersRackmountRackmount/Tower
Rack capacityDiffers2U1U
Cable lengthKnown for one1.83 mUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs0 - 45 °C0 - 40 °C
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Differs0 - 95%0 - 90%
Certificatesidentical
CertificationKnown for oneC-tick, CE, EN 50091-1, EN 50091-2, VDE REACHUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm438.1 mm
DepthDiffers490 mm401.3 mm
HeightDiffers89 mm44.5 mm
WeightDiffers24.8 kg16.3 kg
Packaging data4 differ
Package widthDiffers589 mm528.3 mm
Package depthDiffers620 mm492.8 mm
Package heightDiffers246 mm157.5 mm
Package weightDiffers30 kg19.3 kg
Other featuresidentical
Battery typeKnown for oneAPCRBC115Unknown — not stated by the source
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageKnown for oneUnknown — not stated by the source120 V
Overload protectionKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL1778 4th, cUL CSA C22.2 No 107.3-05, FCC/DOC Class A

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons