Product comparison · 2 uninterruptible power supplies (upss)

APC SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA vs CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA

Add a product
  • 30specifications compared
  • 23differ
  • 7identical
  • 36known for one product only

Key differences

The CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 900 W more output power than the APC SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA (3000 W vs 2100 W). The APC SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA has 55 V more input operation voltage (min) than the CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA (165 V vs 110 V). The CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 10 V more input operation voltage (max) than the APC SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA (300 V vs 290 V). UPS topology: Line-Interactive on the APC SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA, Double-conversion (Online) on the CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA. Waveform: Sine on the APC SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA, Pure sine on the CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA.

  • UPS topology
    • SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:Line-Interactive
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Double-conversion (Online)
  • Output power
    • SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:2100 W
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3000 W
  • Waveform
    • SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:Sine
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Pure sine
  • Input operation voltage (min)
    • SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:165 V
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:110 V
  • Input operation voltage (max)
    • SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:290 V
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:300 V
  • Input frequency
    • SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:45/65 Hz
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:50/60 Hz
  • Output operation voltage (min)
    • SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:220 V
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:200 V
  • Output operation voltage (max)
    • SMV3000CAI-BR uninterruptible power supply (UPS) Line-Interactive 3 kVA:220 V
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of SMV3000CAI-BR, OLS3KERT2UH
66 specifications
Features10 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output powerDiffers2100 W3000 W
WaveformDiffersSinePure sine
Input operation voltage (min)Differs165 V110 V
Input operation voltage (max)Differs290 V300 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Differs220 V200 V
Output operation voltage (max)Differs220 V240 V
Maximum currentKnown for oneUnknown — not stated by the source14.02 A
Surge energy ratingDiffers125 J1065 J
Heat dissipationKnown for oneUnknown — not stated by the source653 BTU/h
Number of input phasesKnown for oneUnknown — not stated by the source1
Efficiency (ECO mode)Known for oneUnknown — not stated by the source98%
Power factorKnown for oneUnknown — not stated by the source1
Input power factorKnown for oneUnknown — not stated by the source0.99
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm modesDiffersAlarm when on battery, Overload alarmAlarm when on battery, Battery replacement, Fault, Low battery alarm, Overload alarm
Response timeKnown for one2 msUnknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersNBR 14136C13 coupler, C19 coupler
AC outlets quantityDiffers6 AC outlet(s)7 AC outlet(s)
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
RS-232 portsKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Battery1 differ
Battery voltageDiffers48 V72 V
Typical backup time at full loadKnown for oneUnknown — not stated by the source2.5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source9.5 min
Charging currentKnown for oneUnknown — not stated by the source8 A
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRBP0160
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Design1 differ
Form factorDiffersCompactRackmount/Tower
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Cable lengthKnown for oneUnknown — not stated by the source1.5 m
Control typeKnown for oneUnknown — not stated by the sourceButtons
Display typeKnown for oneUnknown — not stated by the sourceLCD
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions6 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Differs-10 - 40 °C-20 - 50 °C
Operating relative humidity (H-H)Differs0 - 95%20 - 90%
Storage relative humidity (H-H)Differs0 - 95%10 - 90%
Operating altitudeDiffers0 - 3000 m0 - 1500 m
Non-operating altitudeDiffers0 - 15000 m0 - 1500 m
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceCE, RCM RoHS
Weight & dimensions3 differ
WidthDiffers180 mm540 mm
DepthDiffers455 mm730 mm
HeightDiffers240 mm230 mm
WeightKnown for one24.9 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one592 mmUnknown — not stated by the source
Package depthKnown for one317 mmUnknown — not stated by the source
Package heightKnown for one410 mmUnknown — not stated by the source
Package weightKnown for one27.4 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.