Product comparison · 2 uninterruptible power supplies (upss)

APC SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA vs Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA

Add a product
  • 19specifications compared
  • 15differ
  • 4identical
  • 37known for one product only

Key differences

The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 1 kVA more output power capacity than the APC SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA (3 kVA vs 2 kVA). The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 1,600 W more output power than the APC SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA (3000 W vs 1400 W). The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 55 V more input operation voltage (min) than the APC SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA (220 V vs 165 V). UPS topology: Line-Interactive on the APC SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA, Double-conversion (Online) on the Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA. Input frequency: 45/65 Hz on the APC SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA, 50/60 Hz on the Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA.

  • UPS topology
    • SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:Line-Interactive
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Double-conversion (Online)
  • Output power capacity
    • SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
  • Output power
    • SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:1400 W
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3000 W
  • Input operation voltage (min)
    • SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:165 V
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:220 V
  • Input operation voltage (max)
    • SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:290 V
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
  • Input frequency
    • SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:45/65 Hz
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:50/60 Hz
  • AC outlet types
    • SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:NBR 14136
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:C19 coupler, C13 coupler
  • AC outlets quantity
    • SMV2000CAI-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:6 AC outlet(s)
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:7 AC outlet(s)

Side by side

Differences highlightedShow differences only (on)
Comparison of SMV2000CAI-BR, Keor-DK-3000-B
56 specifications
Features6 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers2 kVA3 kVA
Output powerDiffers1400 W3000 W
Input operation voltage (min)Differs165 V220 V
Input operation voltage (max)Differs290 V240 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Known for one220 VUnknown — not stated by the source
Output operation voltage (max)Known for one220 VUnknown — not stated by the source
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Surge energy ratingKnown for one125 JUnknown — not stated by the source
Response timeKnown for one2 msUnknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
EfficiencyKnown for oneUnknown — not stated by the source98%
Efficiency (On-line mode)Known for oneUnknown — not stated by the source96%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source98.3%
Power factorKnown for oneUnknown — not stated by the source1
Output power factorKnown for oneUnknown — not stated by the source1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersNBR 14136C19 coupler, C13 coupler
AC outlets quantityDiffers6 AC outlet(s)7 AC outlet(s)
Serial ports quantityKnown for one1Unknown — not stated by the source
Network card slotKnown for oneUnknown — not stated by the sourceYes
Battery1 differ
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Battery voltageDiffers48 V12 V
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Number of batteries includedKnown for oneUnknown — not stated by the source6 pc(s)
Number of battery cellsKnown for oneUnknown — not stated by the source6
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Design2 differ
Form factorDiffersCompactRackmount/Tower
Product colourDiffersBlackBlack, White
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Rack capacityKnown for oneUnknown — not stated by the source2U
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-10 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers180 mm440 mm
DepthDiffers455 mm640 mm
HeightDiffers240 mm88 mm
WeightDiffers22.2 kg2.7 kg
Packaging dataidentical
Package widthKnown for one592 mmUnknown — not stated by the source
Package depthKnown for one317 mmUnknown — not stated by the source
Package heightKnown for one410 mmUnknown — not stated by the source
Package weightKnown for one24.4 kgUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Quick installation guideKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons