Product comparison · 2 uninterruptible power supplies (upss)

APC SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA vs Vertiv Liebert Hipulse-U 60kVA

Add a product
  • 12specifications compared
  • 11differ
  • 1identical
  • 29known for one product only

Key differences

The Vertiv Liebert Hipulse-U 60kVA has 58 kVA more output power capacity than the APC SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA (60 kVA vs 2 kVA). The Vertiv Liebert Hipulse-U 60kVA has 295 V more input operation voltage (min) than the APC SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA (380 V vs 85 V). The Vertiv Liebert Hipulse-U 60kVA has 270 V more input operation voltage (max) than the APC SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA (415 V vs 145 V). UPS topology: Line-Interactive on the APC SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA, Double-conversion (Online) on the Vertiv Liebert Hipulse-U 60kVA. Waveform: Sine on the APC SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA, Pure sine on the Vertiv Liebert Hipulse-U 60kVA.

  • UPS topology
    • SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:Line-Interactive
    • Liebert Hipulse-U 60kVA:Double-conversion (Online)
  • Output power capacity
    • SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
    • Liebert Hipulse-U 60kVA:60 kVA
  • Waveform
    • SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:Sine
    • Liebert Hipulse-U 60kVA:Pure sine
  • Input operation voltage (min)
    • SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:85 V
    • Liebert Hipulse-U 60kVA:380 V
  • Input operation voltage (max)
    • SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:145 V
    • Liebert Hipulse-U 60kVA:415 V
  • Input frequency
    • SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:45/65 Hz
    • Liebert Hipulse-U 60kVA:50/60 Hz
  • Form factor
    • SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:Compact
    • Liebert Hipulse-U 60kVA:Rackmount/Tower
  • Operating temperature (T-T)
    • SMV2000CA-BR uninterruptible power supply (UPS) Line-Interactive 2 kVA:0 - 40 °C
    • Liebert Hipulse-U 60kVA:0 - 50 °C

Side by side

Differences highlightedShow differences only (on)
Comparison of SMV2000CA-BR, Liebert Hipulse-U 60kVA
41 specifications
Features6 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers2 kVA60 kVA
Output powerKnown for one1400 WUnknown — not stated by the source
WaveformDiffersSinePure sine
Input operation voltage (min)Differs85 V380 V
Input operation voltage (max)Differs145 V415 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Known for one115 VUnknown — not stated by the source
Output operation voltage (max)Known for one115 VUnknown — not stated by the source
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Surge energy ratingKnown for one150 JUnknown — not stated by the source
Response timeKnown for one2 msUnknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneNBR 14136Unknown — not stated by the source
AC outlets quantityKnown for one6 AC outlet(s)Unknown — not stated by the source
USB portKnown for oneYesUnknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Battery voltageKnown for one48 VUnknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Battery recharge timeKnown for one4 hUnknown — not stated by the source
Design1 differ
Form factorDiffersCompactRackmount/Tower
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Known for one-10 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers180 mm715 mm
DepthDiffers455 mm810 mm
HeightDiffers240 mm1250 mm
WeightKnown for one21 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one592 mmUnknown — not stated by the source
Package depthKnown for one317 mmUnknown — not stated by the source
Package heightKnown for one410 mmUnknown — not stated by the source
Package weightKnown for one30.2 kgUnknown — not stated by the source
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.