Product comparison · 2 uninterruptible power supplies (upss)

APC SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA vs Vertiv Liebert NXC 10kVA

Add a product
  • 16specifications compared
  • 16differ
  • 0identical
  • 41known for one product only

Key differences

The Vertiv Liebert NXC 10kVA has 9.25 kVA more output power capacity than the APC SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA (10 kVA vs 0.75 kVA). The Vertiv Liebert NXC 10kVA has 8,500 W more output power than the APC SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA (9000 W vs 500 W). The Vertiv Liebert NXC 10kVA has 154 V more input operation voltage (min) than the APC SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA (305 V vs 151 V). UPS topology: Line-Interactive on the APC SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA, Double-conversion (Online) on the Vertiv Liebert NXC 10kVA. Input frequency: 47/63 Hz on the APC SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA, 50/60 Hz on the Vertiv Liebert NXC 10kVA.

  • UPS topology
    • SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:Line-Interactive
    • Liebert NXC 10kVA:Double-conversion (Online)
  • Output power capacity
    • SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:0.75 kVA
    • Liebert NXC 10kVA:10 kVA
  • Output power
    • SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:500 W
    • Liebert NXC 10kVA:9000 W
  • Input operation voltage (min)
    • SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:151 V
    • Liebert NXC 10kVA:305 V
  • Input operation voltage (max)
    • SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:302 V
    • Liebert NXC 10kVA:477 V
  • Input frequency
    • SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:47/63 Hz
    • Liebert NXC 10kVA:50/60 Hz
  • Output operation voltage (min)
    • SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:220 V
    • Liebert NXC 10kVA:380 V
  • Output operation voltage (max)
    • SMT750RMI2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:240 V
    • Liebert NXC 10kVA:415 V

Side by side

Differences highlightedShow differences only (off)
Comparison of SMT750RMI2U, Liebert NXC 10kVA
57 specifications
Features10 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers0.75 kVA10 kVA
Output powerDiffers500 W9000 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs151 V305 V
Input operation voltage (max)Differs302 V477 V
Input frequencyDiffers47/63 Hz50/60 Hz
Output operation voltage (min)Differs220 V380 V
Output operation voltage (max)Differs240 V415 V
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one459 JUnknown — not stated by the source
EfficiencyDiffers97.7%98%
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Noise levelDiffers46 dB56 dB
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Input power factorKnown for oneUnknown — not stated by the source0.99
Ports & interfacesidentical
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
Power plugKnown for oneC14 couplerUnknown — not stated by the source
AC outlets quantityKnown for one4 AC outlet(s)Unknown — not stated by the source
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadKnown for one5.5 minUnknown — not stated by the source
Typical backup time at half loadKnown for one16 minUnknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Design2 differ
Form factorDiffersRackmountTower
Product colourDiffersBlack, GreyBlack
Rack capacityKnown for one2UUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneC-tick, CE, EN 50091-1, EN 50091-2, TUV, VDEUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm500 mm
DepthDiffers406 mm860 mm
HeightDiffers89 mm1240 mm
WeightDiffers17.3 kg115 kg
Packaging dataidentical
Package widthKnown for one546 mmUnknown — not stated by the source
Package depthKnown for one584 mmUnknown — not stated by the source
Package heightKnown for one241 mmUnknown — not stated by the source
Package weightKnown for one21.2 kgUnknown — not stated by the source
Other featuresidentical
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Communication options, slotKnown for oneSmartSlotUnknown — not stated by the source
Number of phasesKnown for oneUnknown — not stated by the source3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons