Product comparison · 2 uninterruptible power supplies (upss)

APC SMT3000I uninterruptible power supply (UPS) Line-Interactive 3 kVA vs Vertiv Liebert ItON 800VA

Add a product
  • 36specifications compared
  • 26differ
  • 10identical
  • 40known for one product only

Key differences

  • Output power capacity
    • SMT3000I uninterruptible power supply (UPS) Line-Interactive 3 kVA:3 kVA
    • Liebert ItON 800VA:0.8 kVA
  • Output power
    • SMT3000I uninterruptible power supply (UPS) Line-Interactive 3 kVA:2700 W
    • Liebert ItON 800VA:480 W
  • Waveform
    • SMT3000I uninterruptible power supply (UPS) Line-Interactive 3 kVA:Sine
    • Liebert ItON 800VA:Stepwise
  • Input operation voltage (min)
    • SMT3000I uninterruptible power supply (UPS) Line-Interactive 3 kVA:151 V
    • Liebert ItON 800VA:170 V
  • Input operation voltage (max)
    • SMT3000I uninterruptible power supply (UPS) Line-Interactive 3 kVA:302 V
    • Liebert ItON 800VA:280 V
  • Input frequency
    • SMT3000I uninterruptible power supply (UPS) Line-Interactive 3 kVA:47/63 Hz
    • Liebert ItON 800VA:50/60 Hz
  • AC outlet types
    • SMT3000I uninterruptible power supply (UPS) Line-Interactive 3 kVA:C13 coupler, C19 coupler
    • Liebert ItON 800VA:Type F
  • AC outlets quantity
    • SMT3000I uninterruptible power supply (UPS) Line-Interactive 3 kVA:9 AC outlet(s)
    • Liebert ItON 800VA:2 AC outlet(s)

Side by side

Differences highlightedShow differences only (off)
Comparison of SMT3000I, Liebert ItON 800VA
76 specifications
Features6 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacityDiffers3 kVA0.8 kVA
Output powerDiffers2700 W480 W
WaveformDiffersSineStepwise
Input operation voltage (min)Differs151 V170 V
Input operation voltage (max)Differs302 V280 V
Input frequencyDiffers47/63 Hz50/60 Hz
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Response timeKnown for oneUnknown — not stated by the source6 ms
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Power factorKnown for oneUnknown — not stated by the source0.6
Output power factorKnown for oneUnknown — not stated by the source0.6
Audible alarm(s)YesYes
Output operation voltage (min)Known for one220 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one365 JUnknown — not stated by the source
EfficiencyKnown for one98.1%Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Noise levelKnown for one53 dBUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Ports & interfaces3 differ
AC outlet typesDiffersC13 coupler, C19 couplerType F
AC outlets quantityDiffers9 AC outlet(s)2 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceNo
USB 2.0 ports quantityDiffers10
RS-232 portsKnown for oneUnknown — not stated by the source0
Serial ports quantityKnown for oneUnknown — not stated by the source0
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceNo
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
Battery2 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Typical backup time at half loadDiffers15.1 min3 min
Battery recharge timeDiffers3 h4 h
Typical backup time at full loadKnown for one5.1 minUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Designidentical
Form factorTowerTower
Product colourBlackBlack
LED indicatorsYesYes
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Display typeKnown for oneLCDUnknown — not stated by the source
Operational conditions4 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-15 - 45 °C-20 - 50 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Storage relative humidity (H-H)Differs0 - 95%0 - 90%
Operating altitudeDiffers0 - 3000 m0 - 1500 m
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersC-tick, CE, EN 50091-1, EN 50091-2, VDECE
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceIEC/EN/AS 62040-1-1
Weight & dimensions4 differ
WidthDiffers197 mm101 mm
DepthDiffers544 mm279 mm
HeightDiffers435 mm142 mm
WeightDiffers52.5 kg4.9 kg
Packaging data4 differ
Package widthDiffers381 mm143 mm
Package depthDiffers762 mm327 mm
Package heightDiffers699 mm220 mm
Package weightDiffers63.7 kg5.4 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85078000
Other features2 differ
Battery typeKnown for oneUnknown — not stated by the sourceVRLA
Output connectionsDiffers8 x IEC 320 C13 & 1 x IEC 320 C192 x Schuko
Input connection typeDiffersIEC-320 C20, Schuko CEE 7 / EU1-16P, BS1363ASchuko cord
Dimensions (WxDxH)Known for oneUnknown — not stated by the source101 x 279 x 142 mm
Nominal input voltage230 V230 V
Nominal output voltage230 V230 V
Overload protectionKnown for oneUnknown — not stated by the sourceYes
Package dimensions (WxDxH)Known for oneUnknown — not stated by the source143 x 327 x 22 mm
Non-operating relative humidity (non-condensing)Known for oneUnknown — not stated by the source0 - 90%
Number of phasesKnown for one1Unknown — not stated by the source
Communication options, slotKnown for oneSmartSlotUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons