Product comparison · 2 uninterruptible power supplies (upss)

APC SMT2200RMI2U + WBEXTWAR3YR-SP-04 vs APC SURT15KRMXLI + WBEXTWAR3YR-SP-07

Add a product
  • 39specifications compared
  • 23differ
  • 16identical
  • 9known for one product only

Key differences

  • Output power capacity
    • SMT2200RMI2U + WBEXTWAR3YR-SP-04:2.2 kVA
    • SURT15KRMXLI + WBEXTWAR3YR-SP-07:15 kVA
  • Output power
    • SMT2200RMI2U + WBEXTWAR3YR-SP-04:1980 W
    • SURT15KRMXLI + WBEXTWAR3YR-SP-07:12000 W
  • Input operation voltage (min)
    • SMT2200RMI2U + WBEXTWAR3YR-SP-04:151 V
    • SURT15KRMXLI + WBEXTWAR3YR-SP-07:160 V
  • Input operation voltage (max)
    • SMT2200RMI2U + WBEXTWAR3YR-SP-04:302 V
    • SURT15KRMXLI + WBEXTWAR3YR-SP-07:400 V
  • Input frequency
    • SMT2200RMI2U + WBEXTWAR3YR-SP-04:50/60 Hz
    • SURT15KRMXLI + WBEXTWAR3YR-SP-07:40/70 Hz
  • Output operation voltage (max)
    • SMT2200RMI2U + WBEXTWAR3YR-SP-04:240 V
    • SURT15KRMXLI + WBEXTWAR3YR-SP-07:415 V
  • Output frequency regulation
    • SMT2200RMI2U + WBEXTWAR3YR-SP-04:3 Hz
    • SURT15KRMXLI + WBEXTWAR3YR-SP-07:0.1 Hz
  • Efficiency
    • SMT2200RMI2U + WBEXTWAR3YR-SP-04:98.3%
    • SURT15KRMXLI + WBEXTWAR3YR-SP-07:94.8%

Side by side

Differences highlightedShow differences only (off)
Comparison of SMT2200RMI2U + WBEXTWAR3YR-SP-04, SURT15KRMXLI + WBEXTWAR3YR-SP-07
48 specifications
Features9 differ
Output power capacityDiffers2.2 kVA15 kVA
Output powerDiffers1980 W12000 W
WaveformSineSine
Input operation voltage (min)Differs151 V160 V
Input operation voltage (max)Differs302 V400 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output operation voltage (min)220 V220 V
Output operation voltage (max)Differs240 V415 V
Output frequency regulationDiffers3 Hz0.1 Hz
Automatic Voltage Regulation (AVR)YesYes
Maximum currentKnown for oneUnknown — not stated by the source100 A
EfficiencyDiffers98.3%94.8%
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Input current Total Harmonic Distortion (THD)5%5%
Noise levelDiffers55 dB50 dB
Surge protectionYesYes
Audible alarm(s)YesYes
Surge energy ratingKnown for one375 JUnknown — not stated by the source
Ports & interfaces3 differ
AC outlet typesDiffersC13 coupler, C19 couplerC19 coupler
AC outlets quantityDiffers9 AC outlet(s)10 AC outlet(s)
Number of output IEC jumpersDiffers32
Power plugKnown for oneC20 couplerUnknown — not stated by the source
Battery1 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery voltageKnown for oneUnknown — not stated by the source192 V
Battery recharge timeDiffers3 h2.5 h
Design1 differ
Product colourBlackBlack
Rack capacityDiffers2U12U
Display typeLCDLCD
Form factorKnown for oneRackmount/TowerUnknown — not stated by the source
Cable lengthKnown for one2 mUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Certificatesidentical
Compliance certificatesRoHSRoHS
Weight & dimensions4 differ
WidthDiffers480 mm432 mm
DepthDiffers683 mm773 mm
HeightDiffers86 mm533 mm
WeightDiffers42.3 kg247.7 kg
Packaging data4 differ
Package widthDiffers600 mm610 mm
Package depthDiffers980 mm1003 mm
Package heightDiffers254 mm990 mm
Package weightDiffers42.7 kg314.1 kg
Other features1 differ
Battery typeDiffersRBC43RBC44

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons