Product comparison · 2 uninterruptible power supplies (upss)

APC SMT2200I uninterruptible power supply (UPS) Line-Interactive 2.2 kVA vs Vertiv Liebert NXC 10kVA

Add a product
  • 17specifications compared
  • 15differ
  • 2identical
  • 39known for one product only

Key differences

  • UPS topology
    • SMT2200I uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:Line-Interactive
    • Liebert NXC 10kVA:Double-conversion (Online)
  • Output power capacity
    • SMT2200I uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
    • Liebert NXC 10kVA:10 kVA
  • Output power
    • SMT2200I uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:1980 W
    • Liebert NXC 10kVA:9000 W
  • Input operation voltage (min)
    • SMT2200I uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:151 V
    • Liebert NXC 10kVA:305 V
  • Input operation voltage (max)
    • SMT2200I uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:302 V
    • Liebert NXC 10kVA:477 V
  • Input frequency
    • SMT2200I uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:47/63 Hz
    • Liebert NXC 10kVA:50/60 Hz
  • Output operation voltage (min)
    • SMT2200I uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:220 V
    • Liebert NXC 10kVA:380 V
  • Output operation voltage (max)
    • SMT2200I uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:240 V
    • Liebert NXC 10kVA:415 V

Side by side

Differences highlightedShow differences only (on)
Comparison of SMT2200I, Liebert NXC 10kVA
56 specifications
Features10 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers2.2 kVA10 kVA
Output powerDiffers1980 W9000 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs151 V305 V
Input operation voltage (max)Differs302 V477 V
Input frequencyDiffers47/63 Hz50/60 Hz
Output operation voltage (min)Differs220 V380 V
Output operation voltage (max)Differs240 V415 V
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one365 JUnknown — not stated by the source
EfficiencyDiffers97.9%98%
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Noise levelDiffers45 dB56 dB
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Input power factorKnown for oneUnknown — not stated by the source0.99
Ports & interfacesidentical
AC outlet typesKnown for oneC13 coupler, C19 couplerUnknown — not stated by the source
AC outlets quantityKnown for one9 AC outlet(s)Unknown — not stated by the source
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadKnown for one8.5 minUnknown — not stated by the source
Typical backup time at half loadKnown for one24.6 minUnknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Designidentical
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneCE, EN 50091-1, EN 50091-2, VDEUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers197 mm500 mm
DepthDiffers544 mm860 mm
HeightDiffers435 mm1240 mm
WeightDiffers48.8 kg115 kg
Packaging dataidentical
Package widthKnown for one381 mmUnknown — not stated by the source
Package depthKnown for one762 mmUnknown — not stated by the source
Package heightKnown for one699 mmUnknown — not stated by the source
Package weightKnown for one61.9 kgUnknown — not stated by the source
Other features1 differ
Number of phasesDiffers13
Output connectionsKnown for one8 x IEC 320 C13 & 1 x IEC 320 C19Unknown — not stated by the source
Input connection typeKnown for oneIEC-320 C20, Schuko CEE 7 / EU1-16P, BS1363AUnknown — not stated by the source
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Communication options, slotKnown for oneSmartSlotUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.