Product comparison · 2 uninterruptible power supplies (upss)

APC SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA vs CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA

Add a product
  • 31specifications compared
  • 17differ
  • 14identical
  • 34known for one product only

Key differences

The APC SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 1.2 kVA more output power capacity than the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA (2.2 kVA vs 1 kVA). The APC SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 1,180 W more output power than the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA (1980 W vs 800 W). The APC SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 182 V more input operation voltage (max) than the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA (302 V vs 120 V). AC outlet types: C13 coupler, C19 coupler on the APC SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA, NEMA 5–15R on the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA. AC outlets quantity: 9 AC outlet(s) on the APC SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA, 7 AC outlet(s) on the CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA.

  • Output power capacity
    • SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:1 kVA
  • Output power
    • SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:1980 W
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:800 W
  • Input operation voltage (max)
    • SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:302 V
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:120 V
  • Output operation voltage (max)
    • SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:240 V
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:120 V
  • Surge energy rating
    • SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:365 J
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:1030 J
  • AC outlet types
    • SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:C13 coupler, C19 coupler
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:NEMA 5–15R
  • AC outlets quantity
    • SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:9 AC outlet(s)
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:7 AC outlet(s)
  • Battery recharge time
    • SMT2200I-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:3 h
    • PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:6 h

Side by side

Differences highlightedShow differences only (on)
Comparison of SMT2200I-BNDL, PR1000LCDRT1U
65 specifications
Features5 differ
Output power capacityDiffers2.2 kVA1 kVA
Output powerDiffers1980 W800 W
Input operation voltage (min)Known for one151 VUnknown — not stated by the source
Input operation voltage (max)Differs302 V120 V
Output operation voltage (min)Known for one220 VUnknown — not stated by the source
Output operation voltage (max)Differs240 V120 V
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingDiffers365 J1030 J
EfficiencyKnown for one97.9%Unknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Output frequencyKnown for oneUnknown — not stated by the source60 Hz
Power factorKnown for oneUnknown — not stated by the source0.8
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5–15R
AC outlets quantityDiffers9 AC outlet(s)7 AC outlet(s)
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15P
Serial ports quantityKnown for oneUnknown — not stated by the source1
Battery1 differ
Battery recharge timeDiffers3 h6 h
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Number of batteries supportedKnown for oneUnknown — not stated by the source4
Typical backup time at full loadKnown for oneUnknown — not stated by the source3.5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source13 min
Designidentical
Form factorKnown for oneUnknown — not stated by the sourceRackmount/Tower
Rack capacityKnown for oneUnknown — not stated by the source1U
Operational conditions1 differ
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Differs0 - 95%0 - 90%
Certificatesidentical
CertificationKnown for oneCE, EN 50091-1, EN 50091-2, VDE REACHUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers197 mm438.1 mm
DepthDiffers544 mm401.3 mm
HeightDiffers435 mm44.5 mm
WeightDiffers48.8 kg16.3 kg
Packaging data4 differ
Package widthDiffers381 mm528.3 mm
Package depthDiffers762 mm492.8 mm
Package heightDiffers699 mm157.5 mm
Package weightDiffers61.9 kg19.3 kg
Other featuresidentical
Battery typeKnown for oneRBC55Unknown — not stated by the source
Output connectionsKnown for one8 x C13 & 1 x C19Unknown — not stated by the source
Input connection typeKnown for oneBS1363A & IEC-320 C20 & Schuko CEE 7/EU1-16PUnknown — not stated by the source
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageKnown for oneUnknown — not stated by the source120 V
Overload protectionKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL1778 4th, cUL CSA C22.2 No 107.3-05, FCC/DOC Class A

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.