Product comparison · 2 uninterruptible power supplies (upss)

APC SMT1500I-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA vs APC SMX2200HV-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA

Add a product
  • 46specifications compared
  • 20differ
  • 26identical
  • 8known for one product only

Key differences

  • Output power capacity
    • SMT1500I-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • SMX2200HV-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
  • Output power
    • SMT1500I-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1000 W
    • SMX2200HV-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:1980 W
  • Input operation voltage (min)
    • SMT1500I-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:151 V
    • SMX2200HV-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:140 V
  • Input operation voltage (max)
    • SMT1500I-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:302 V
    • SMX2200HV-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:280 V
  • Output operation voltage (min)
    • SMT1500I-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:220 V
    • SMX2200HV-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:208 V
  • Surge energy rating
    • SMT1500I-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:459 J
    • SMX2200HV-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:645 J
  • Efficiency
    • SMT1500I-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:98.2%
    • SMX2200HV-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:98.1%
  • Emergency Power Off (EPO)
    • SMT1500I-BNDL uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:No
    • SMX2200HV-BNDL uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:Yes

Side by side

Differences highlightedShow differences only (on)
Comparison of SMT1500I-BNDL, SMX2200HV-BNDL
54 specifications
Features8 differ
Output power capacityDiffers1.5 kVA2.2 kVA
Output powerDiffers1000 W1980 W
Input operation voltage (min)Differs151 V140 V
Input operation voltage (max)Differs302 V280 V
Output operation voltage (min)Differs220 V208 V
Surge energy ratingDiffers459 J645 J
EfficiencyDiffers98.2%98.1%
Emergency Power Off (EPO)DiffersNoYes
Noise levelKnown for one45 dBUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Power plugKnown for oneC14 couplerUnknown — not stated by the source
AC outlets quantityDiffers8 AC outlet(s)10 AC outlet(s)
Batteryidentical
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Designidentical
Form factorKnown for oneUnknown — not stated by the sourceRackmount
Rack capacityKnown for oneUnknown — not stated by the source4U
Certificates1 differ
CertificationDiffersC-tick, CE, EN 50091-1, EN 50091-2, VDE REACHC-tick, CE, CSA, EN 50091-1, EN 50091-2, FCC Part 15 Class A, GOST, IEC 60950, IRAM, UL 1778, VDE REACH
Weight & dimensions4 differ
WidthDiffers171 mm178 mm
DepthDiffers439 mm483 mm
HeightDiffers219 mm432 mm
WeightDiffers24.1 kg38.6 kg
Packaging data4 differ
Package widthDiffers328 mm586 mm
Package depthDiffers595 mm633 mm
Package heightDiffers376 mm330 mm
Package weightDiffers27.2 kg47.7 kg
Other features1 differ
Nominal input voltageDiffers230 V208-230 V
Output connectionsKnown for oneUnknown — not stated by the source8 x C13 & 2 x C19
Input connection typeKnown for oneUnknown — not stated by the sourceBS1363A & IEC-320 C20 & Schuko CEE 7/EU1-16P

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons