The APC Smart-UPS XL 2200VA has 250 W more output power than the APC Smart-UPS XL 2200VA RM (1850 W vs 1600 W). The APC Smart-UPS XL 2200VA RM has 480 J more surge energy rating than the APC Smart-UPS XL 2200VA (960 J vs 480 J). The APC Smart-UPS XL 2200VA has 0.7 min more typical backup time at full load than the APC Smart-UPS XL 2200VA RM (10.4 min vs 9.7 min). Input connection type: NEMA 5-20P on the APC Smart-UPS XL 2200VA, NEMA L6-20P on the APC Smart-UPS XL 2200VA RM. Dimensions (WxDxH): 196 x 503 x 432 mm on the APC Smart-UPS XL 2200VA, 483 x 451 x 222 mm on the APC Smart-UPS XL 2200VA RM.

  • Output power
    • Smart-UPS XL 2200VA:1850 W
    • Smart-UPS XL 2200VA RM:1600 W
  • Surge energy rating
    • Smart-UPS XL 2200VA:480 J
    • Smart-UPS XL 2200VA RM:960 J
  • Typical backup time at full load
    • Smart-UPS XL 2200VA:10.4 min
    • Smart-UPS XL 2200VA RM:9.7 min
  • Typical backup time at half load
    • Smart-UPS XL 2200VA:28.5 min
    • Smart-UPS XL 2200VA RM:34.3 min
  • Weight
    • Smart-UPS XL 2200VA:55 kg
    • Smart-UPS XL 2200VA RM:6 kg
  • Input connection type
    • Smart-UPS XL 2200VA:NEMA 5-20P
    • Smart-UPS XL 2200VA RM:NEMA L6-20P
  • Dimensions (WxDxH)
    • Smart-UPS XL 2200VA:196 x 503 x 432 mm
    • Smart-UPS XL 2200VA RM:483 x 451 x 222 mm
  • Nominal input voltage
    • Smart-UPS XL 2200VA:120 V
    • Smart-UPS XL 2200VA RM:208 V

Side by side

Differences highlightedShow differences only (off)
Comparison of Smart-UPS XL 2200VA, Smart-UPS XL 2200VA RM
34 specifications
Features2 differ
Output power capacity2.2 kVA2.2 kVA
Output powerDiffers1850 W1600 W
Input frequencyKnown for one50/60 HzUnknown — not stated by the source
Surge energy ratingDiffers480 J960 J
Emergency Power Off (EPO)YesYes
Noise level53 dB53 dB
Audible alarm(s)YesYes
Battery2 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadDiffers10.4 min9.7 min
Typical backup time at half loadDiffers28.5 min34.3 min
Battery recharge time3 h3 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceNo
Designidentical
Cable lengthKnown for one2.44 mUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Product colourKnown for oneUnknown — not stated by the sourceBeige
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneCSA,FCC Part 15 Class A,UL 1778Unknown — not stated by the source
Weight & dimensions1 differ
WeightDiffers55 kg6 kg
Other features5 differ
InterfaceKnown for oneDB-9 RS-232,Smart-Slot,USBUnknown — not stated by the source
Output connectionsDiffers(9) NEMA 5-15R (2) NEMA 5-20R2X NEMA 5-15R 1X NEMA L6-20R 2X NEMA L6-30R
Input connection typeDiffersNEMA 5-20PNEMA L6-20P
Dimensions (WxDxH)Differs196 x 503 x 432 mm483 x 451 x 222 mm
Nominal input voltageDiffers120 V208 V
Nominal output voltageDiffers120 V208 V
Filtering descriptionKnown for oneUnknown — not stated by the source0.3%
Output voltage noteKnown for oneUnknown — not stated by the source400
Non-operating relative humidity (non-condensing)Known for oneUnknown — not stated by the source0 - 95%
Ports & interfacesidentical
Serial ports quantityKnown for oneUnknown — not stated by the source1
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source68.6 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.