Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS X 3000VA vs APC Smart-UPS RT 3000VA

Add a product
  • 44specifications compared
  • 26differ
  • 18identical
  • 21known for one product only

Key differences

  • UPS topology
    • Smart-UPS X 3000VA:Line-Interactive
    • Smart-UPS RT 3000VA:Double-conversion (Online)
  • Output power
    • Smart-UPS X 3000VA:2700 W
    • Smart-UPS RT 3000VA:2100 W
  • Input operation voltage (min)
    • Smart-UPS X 3000VA:100 V
    • Smart-UPS RT 3000VA:160 V
  • Input operation voltage (max)
    • Smart-UPS X 3000VA:127 V
    • Smart-UPS RT 3000VA:280 V
  • Input frequency
    • Smart-UPS X 3000VA:50/60 Hz
    • Smart-UPS RT 3000VA:40/70 Hz
  • Output operation voltage (min)
    • Smart-UPS X 3000VA:100 V
    • Smart-UPS RT 3000VA:220 V
  • Output operation voltage (max)
    • Smart-UPS X 3000VA:127 V
    • Smart-UPS RT 3000VA:240 V
  • Surge energy rating
    • Smart-UPS X 3000VA:540 J
    • Smart-UPS RT 3000VA:480 J

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart-UPS X 3000VA, SURT3000XLIX554
65 specifications
B

APC

Smart-UPS RT 3000VA

Model SURT3000XLIX554

View product
Features11 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output powerDiffers2700 W2100 W
Input operation voltage (min)Differs100 V160 V
Input operation voltage (max)Differs127 V280 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output operation voltage (min)Differs100 V220 V
Output operation voltage (max)Differs127 V240 V
Surge energy ratingDiffers540 J480 J
EfficiencyDiffers98%92%
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Differs5%3%
Audible alarm modesDiffersAlarm when on battery, Low battery alarmAlarm when on battery, Low battery alarm, Overload alarm
Auto-restartKnown for oneUnknown — not stated by the sourceYes
Heat dissipationKnown for one276 BTU/hUnknown — not stated by the source
Number of output phasesKnown for one1Unknown — not stated by the source
Surge protection featuresKnown for oneNetworkUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5–15R, NEMA 5–20R, NEMA L5-30RC13 coupler, C19 coupler, IEC Jumpers
AC outlets quantityDiffers7 AC outlet(s)13 AC outlet(s)
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Battery2 differ
Battery technologyDiffersLead-AcidSealed Lead Acid (VRLA)
Battery recharge timeDiffers3 h2.5 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Automatic battery testKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceAPCRBC140
Typical backup time at full loadKnown for one6.15 minUnknown — not stated by the source
Designidentical
Product colourKnown for oneBlackUnknown — not stated by the source
Rack capacityKnown for one2UUnknown — not stated by the source
Control typeKnown for oneButtonsUnknown — not stated by the source
Operational conditions1 differ
Operating altitudeDiffers0 - 3000 m0 - 3048 m
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceRS-232
ManualKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
CertificationDiffersBSMI,CSA,EN 50091-2,EN 55022 A,FCC 15 A,NOM,TUV,UL 1778,VCCI AEN/IEC 62040-1-1, EN/IEC 62040-2, GOST, VDE
Weight & dimensions4 differ
WidthDiffers432 mm130 mm
DepthDiffers667 mm660 mm
HeightDiffers85 mm432 mm
WeightDiffers38.5 kg54.7 kg
Packaging data4 differ
Package widthDiffers869 mm603 mm
Package depthDiffers596 mm980 mm
Package heightDiffers243 mm347 mm
Package weightDiffers45.4 kg63.6 kg
Logistics data1 differ
Harmonized System (HS) codeDiffers8504.4085078000
Total carbon footprint (kg of CO2e)Known for oneUnknown — not stated by the source4310.05
Export Control Classification Number (ECCN)Known for oneEAR99Unknown — not stated by the source
Other featuresidentical
Battery typeKnown for oneRBC117Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons