Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS VT 30kVA UPS vs APC Symmetra PX 10kVA UPS enclosure

Add a product
  • 12specifications compared
  • 6differ
  • 6identical
  • 10known for one product only

Key differences

The APC Smart-UPS VT 30kVA UPS has 20 kVA more output power capacity than the APC Symmetra PX 10kVA UPS enclosure (30 kVA vs 10 kVA). The APC Smart-UPS VT 30kVA UPS has 14,000 W more output power than the APC Symmetra PX 10kVA UPS enclosure (24000 W vs 10000 W). The APC Symmetra PX 10kVA UPS enclosure has 6 dB more noise level than the APC Smart-UPS VT 30kVA UPS (64 dB vs 58 dB). Storage temperature (T-T): -50 - 40 °C on the APC Smart-UPS VT 30kVA UPS, -15 - 40 °C on the APC Symmetra PX 10kVA UPS enclosure. Operating altitude: 0 - 9999.9 m on the APC Smart-UPS VT 30kVA UPS, 0 - 3000 m on the APC Symmetra PX 10kVA UPS enclosure.

  • Output power capacity
    • Smart-UPS VT 30kVA UPS:30 kVA
    • Symmetra PX 10kVA UPS enclosure:10 kVA
  • Output power
    • Smart-UPS VT 30kVA UPS:24000 W
    • Symmetra PX 10kVA UPS enclosure:10000 W
  • Noise level
    • Smart-UPS VT 30kVA UPS:58 dB
    • Symmetra PX 10kVA UPS enclosure:64 dB
  • Storage temperature (T-T)
    • Smart-UPS VT 30kVA UPS:-50 - 40 °C
    • Symmetra PX 10kVA UPS enclosure:-15 - 40 °C
  • Operating altitude
    • Smart-UPS VT 30kVA UPS:0 - 9999.9 m
    • Symmetra PX 10kVA UPS enclosure:0 - 3000 m
  • Weight
    • Smart-UPS VT 30kVA UPS:1040.9 kg
    • Symmetra PX 10kVA UPS enclosure:662.3 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart-UPS VT 30kVA UPS, Symmetra PX 10kVA UPS enclosure
22 specifications
Features3 differ
Output power capacityDiffers30 kVA10 kVA
Output powerDiffers24000 W10000 W
Noise levelDiffers58 dB64 dB
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadKnown for oneUnknown — not stated by the source3.6 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source13.8 min
Battery recharge timeKnown for oneUnknown — not stated by the source2 h
Operational conditions2 differ
Storage temperature (T-T)Differs-50 - 40 °C-15 - 40 °C
Operating altitudeDiffers0 - 9999.9 m0 - 3000 m
Weight & dimensions1 differ
WeightDiffers1040.9 kg662.3 kg
Other featuresidentical
Battery typeKnown for oneVRLAUnknown — not stated by the source
Nominal input voltageKnown for one208 VUnknown — not stated by the source
Package dimensions (WxDxH)Known for one600 x 1075 x 1995 mmUnknown — not stated by the source
Output connectionsKnown for oneUnknown — not stated by the source(1) Hard Wire 5-wire (3PH + N + G) (1) Screw Terminals
Dimensions (WxDxH)Known for oneUnknown — not stated by the source1219 x 902 x 2070 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.