Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS VT 30kVA Rack-mountable UPS vs APC Symmetra RM 8kVA Scalable UPS

Add a product
  • 18specifications compared
  • 11differ
  • 7identical
  • 11known for one product only

Key differences

The APC Smart-UPS VT 30kVA Rack-mountable UPS has 22 kVA more output power capacity than the APC Symmetra RM 8kVA Scalable UPS (30 kVA vs 8 kVA). The APC Smart-UPS VT 30kVA Rack-mountable UPS has 18,400 W more output power than the APC Symmetra RM 8kVA Scalable UPS (24000 W vs 5600 W). The APC Symmetra RM 8kVA Scalable UPS has 4 dB more noise level than the APC Smart-UPS VT 30kVA Rack-mountable UPS (62 dB vs 58 dB). Storage temperature (T-T): -50 - 40 °C on the APC Smart-UPS VT 30kVA Rack-mountable UPS, -15 - 45 °C on the APC Symmetra RM 8kVA Scalable UPS. Input connection type: Hard Wire 5-wire (3PH + N + G) on the APC Smart-UPS VT 30kVA Rack-mountable UPS, Hard Wire 3-wire (2PH + G) on the APC Symmetra RM 8kVA Scalable UPS.

  • Output power capacity
    • Smart-UPS VT 30kVA Rack-mountable UPS:30 kVA
    • Symmetra RM 8kVA Scalable UPS:8 kVA
  • Output power
    • Smart-UPS VT 30kVA Rack-mountable UPS:24000 W
    • Symmetra RM 8kVA Scalable UPS:5600 W
  • Noise level
    • Smart-UPS VT 30kVA Rack-mountable UPS:58 dB
    • Symmetra RM 8kVA Scalable UPS:62 dB
  • Typical backup time at full load
    • Smart-UPS VT 30kVA Rack-mountable UPS:9.5 min
    • Symmetra RM 8kVA Scalable UPS:5.1 min
  • Typical backup time at half load
    • Smart-UPS VT 30kVA Rack-mountable UPS:27.1 min
    • Symmetra RM 8kVA Scalable UPS:16.7 min
  • Storage temperature (T-T)
    • Smart-UPS VT 30kVA Rack-mountable UPS:-50 - 40 °C
    • Symmetra RM 8kVA Scalable UPS:-15 - 45 °C
  • Weight
    • Smart-UPS VT 30kVA Rack-mountable UPS:747.3 kg
    • Symmetra RM 8kVA Scalable UPS:205.9 kg
  • Dimensions (WxDxH)
    • Smart-UPS VT 30kVA Rack-mountable UPS:600 X 1075 X 1995 mm
    • Symmetra RM 8kVA Scalable UPS:483 x 737 x 756 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of Smart-UPS VT 30kVA Rack-mountable UPS, Symmetra RM 8kVA Scalable UPS
29 specifications
Features3 differ
Output power capacityDiffers30 kVA8 kVA
Output powerDiffers24000 W5600 W
Input frequencyKnown for oneUnknown — not stated by the source60 Hz
Emergency Power Off (EPO)YesYes
Noise levelDiffers58 dB62 dB
Audible alarm(s)YesYes
Battery2 differ
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Typical backup time at full loadDiffers9.5 min5.1 min
Typical backup time at half loadDiffers27.1 min16.7 min
Battery recharge time3 h3 h
Designidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Product colourKnown for oneBlackUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-50 - 40 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceCSA,FCC 15 A,UL 1778
Weight & dimensions1 differ
WeightDiffers747.3 kg205.9 kg
Other features4 differ
InterfaceDiffers1DB-9 RS-232,RJ-45 10 Base-T ethernet/ SNMP/ Telnet,SmartSlot
Output connectionsDiffers1 X Hard Wire 5-wire (3PH + N + G) 5 X NEMA L21-20(1) Hard Wire 3-wire (2PH + G) (12) NEMA 5-20R (6) NEMA L6-20R (2) NEMA L6-30R
Input connection typeDiffersHard Wire 5-wire (3PH + N + G)Hard Wire 3-wire (2PH + G)
Dimensions (WxDxH)Differs600 X 1075 X 1995 mm483 x 737 x 756 mm
Nominal input voltage208 V208 V
Battery typeKnown for oneVRLAUnknown — not stated by the source
Output voltage noteKnown for one200: 208 or 220V 3 Phase nominal output voltageUnknown — not stated by the source
Package dimensions (WxDxH)Known for one600 X 1075 X 1995 mmUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one782.3 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons