Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS VT 15kVA vs Trust 750VA UPS PW-4075T

Add a product
  • 4specifications compared
  • 3differ
  • 1identical
  • 14known for one product only

Key differences

The APC Smart-UPS VT 15kVA has 14.25 kVA more output power capacity than the Trust 750VA UPS PW-4075T (15 kVA vs 0.75 kVA). The Trust 750VA UPS PW-4075T has 6.9 min more typical backup time at half load than the APC Smart-UPS VT 15kVA (35 min vs 28.1 min). Dimensions (WxDxH): 523 x 925 x 1499 mm on the APC Smart-UPS VT 15kVA, 105 x 338 x 147 mm on the Trust 750VA UPS PW-4075T.

  • Output power capacity
    • Smart-UPS VT 15kVA:15 kVA
    • 750VA UPS PW-4075T:0.75 kVA
  • Typical backup time at half load
    • Smart-UPS VT 15kVA:28.1 min
    • 750VA UPS PW-4075T:35 min
  • Dimensions (WxDxH)
    • Smart-UPS VT 15kVA:523 x 925 x 1499 mm
    • 750VA UPS PW-4075T:105 x 338 x 147 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart-UPS VT 15kVA, 750VA UPS PW-4075T
18 specifications
Features1 differ
Output power capacityDiffers15 kVA0.75 kVA
Output powerKnown for one12000 WUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for oneUnknown — not stated by the source150 J
Battery1 differ
Typical backup time at full loadKnown for one10 minUnknown — not stated by the source
Typical backup time at half loadDiffers28.1 min35 min
Battery recharge timeKnown for one5 hUnknown — not stated by the source
Replacement battery cartridgeKnown for oneSYBT4Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-50 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 999.9 mUnknown — not stated by the source
Weight & dimensionsidentical
WeightKnown for one415 kgUnknown — not stated by the source
Other features1 differ
Battery typeKnown for oneVRLAUnknown — not stated by the source
Dimensions (WxDxH)Differs523 x 925 x 1499 mm105 x 338 x 147 mm
Nominal input voltageKnown for one208 VUnknown — not stated by the source
I/O portsKnown for oneUnknown — not stated by the sourceRJ-11

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons