Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS RT 6000VA vs CyberPower OR1000LCDRM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA

Add a product
  • 22specifications compared
  • 17differ
  • 5identical
  • 45known for one product only

Key differences

  • UPS topology
    • Smart-UPS RT 6000VA:Double-conversion (Online)
    • OR1000LCDRM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:Line-Interactive
  • Output power capacity
    • Smart-UPS RT 6000VA:6 kVA
    • OR1000LCDRM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:1 kVA
  • Output power
    • Smart-UPS RT 6000VA:4200 W
    • OR1000LCDRM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:600 W
  • Input operation voltage (min)
    • Smart-UPS RT 6000VA:85 V
    • OR1000LCDRM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:90 V
  • Input operation voltage (max)
    • Smart-UPS RT 6000VA:236 V
    • OR1000LCDRM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:140 V
  • Input frequency
    • Smart-UPS RT 6000VA:50/60 Hz
    • OR1000LCDRM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:60 Hz
  • Surge energy rating
    • Smart-UPS RT 6000VA:480 J
    • OR1000LCDRM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:1030 J
  • Power plug
    • Smart-UPS RT 6000VA:NEMA L14-30P
    • OR1000LCDRM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA:C14 coupler

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart-UPS RT 6000VA, OR1000LCDRM1U
67 specifications
Features7 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers6 kVA1 kVA
Output powerDiffers4200 W600 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs85 V90 V
Input operation voltage (max)Differs236 V140 V
Input frequencyDiffers50/60 Hz60 Hz
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Output voltage regulationKnown for one5%Unknown — not stated by the source
Surge energy ratingDiffers480 J1030 J
Heat dissipationKnown for one1780 BTU/hUnknown — not stated by the source
EfficiencyKnown for one90%Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one2%Unknown — not stated by the source
Noise levelKnown for one55 dBUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarmUnknown — not stated by the source
Output operation voltage (max)Known for oneUnknown — not stated by the source120 V
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Response timeKnown for oneUnknown — not stated by the source4 ms
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5-20R, NEMA L6-30R, NEMA L14-30RNEMA 5–15R
Power plugDiffersNEMA L14-30PC14 coupler
AC outlets quantityKnown for one6 AC outlet(s)Unknown — not stated by the source
USB portKnown for oneYesUnknown — not stated by the source
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Network card slotKnown for oneYesUnknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Battery2 differ
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Number of batteries includedKnown for one2 pc(s)Unknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Battery recharge timeDiffers2.5 h8 h
Replacement battery cartridgeDiffersAPCRBC140BB - BP7-6
Number of batteries supportedKnown for oneUnknown — not stated by the source4
Typical backup time at full loadKnown for oneUnknown — not stated by the source3 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source13 min
Design1 differ
Rack capacityDiffers3U1U
Cable lengthKnown for one3.05 mUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Display typeKnown for oneUnknown — not stated by the sourceLCD
Operational conditionsidentical
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Packaging contentidentical
Rack mount kitKnown for oneYesUnknown — not stated by the source
Management card includedKnown for oneYesUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCSA,FCC Part 15 Class A,UL 1778UL1778, cUL 107.1, FCC DOC B
Weight & dimensions4 differ
WidthDiffers432 mm438 mm
DepthDiffers660 mm400.5 mm
HeightDiffers130 mm44.4 mm
WeightDiffers58.1 kg16.1 kg
Packaging dataidentical
Package widthKnown for one980 mmUnknown — not stated by the source
Package depthKnown for one603 mmUnknown — not stated by the source
Package heightKnown for one347 mmUnknown — not stated by the source
Package weightKnown for one72.3 kgUnknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR