Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS RT 6000VA RM vs APC SURT10000XLI Kit

Add a product
  • 20specifications compared
  • 8differ
  • 12identical
  • 13known for one product only

Key differences

The APC SURT10000XLI Kit has 4 kVA more output power capacity than the APC Smart-UPS RT 6000VA RM (10 kVA vs 6 kVA). The APC SURT10000XLI Kit has 3,800 W more output power than the APC Smart-UPS RT 6000VA RM (8000 W vs 4200 W). The APC SURT10000XLI Kit has 1 dB more noise level than the APC Smart-UPS RT 6000VA RM (56 dB vs 55 dB). Dimensions (WxDxH): 432 x 660 x 130 mm on the APC Smart-UPS RT 6000VA RM, 430 x 660 x 260 mm on the APC SURT10000XLI Kit.

  • Output power capacity
    • Smart-UPS RT 6000VA RM:6 kVA
    • SURT10000XLI Kit:10 kVA
  • Output power
    • Smart-UPS RT 6000VA RM:4200 W
    • SURT10000XLI Kit:8000 W
  • Noise level
    • Smart-UPS RT 6000VA RM:55 dB
    • SURT10000XLI Kit:56 dB
  • Operating relative humidity (H-H)
    • Smart-UPS RT 6000VA RM:0 - 95%
    • SURT10000XLI Kit:5 - 95%
  • Storage relative humidity (H-H)
    • Smart-UPS RT 6000VA RM:0 - 95%
    • SURT10000XLI Kit:5 - 95%
  • Weight
    • Smart-UPS RT 6000VA RM:54.5 kg
    • SURT10000XLI Kit:111 kg
  • Dimensions (WxDxH)
    • Smart-UPS RT 6000VA RM:432 x 660 x 130 mm
    • SURT10000XLI Kit:430 x 660 x 260 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart-UPS RT 6000VA RM, SURT10000XLI Kit
33 specifications
Features3 differ
Output power capacityDiffers6 kVA10 kVA
Output powerDiffers4200 W8000 W
Noise levelDiffers55 dB56 dB
Ports & interfacesidentical
Number of output IEC jumpersKnown for one4Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
Batteryidentical
Battery recharge timeKnown for one2.5 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Typical backup time at full loadKnown for oneUnknown — not stated by the source4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source13.2 min
Operational conditions2 differ
Operating relative humidity (H-H)Differs0 - 95%5 - 95%
Storage relative humidity (H-H)Differs0 - 95%5 - 95%
Certificatesidentical
CertificationKnown for oneC-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, VDEUnknown — not stated by the source
Weight & dimensions1 differ
WeightDiffers54.5 kg111 kg
Packaging dataidentical
Package weightKnown for one63.6 kgUnknown — not stated by the source
Other features2 differ
Output connectionsDiffers8 x IEC 320 C13 2 x IEC 320 C191 x Hard Wire 3-wire (H N + G) 4 x IEC 320 C13 4 x IEC 320 C19
Dimensions (WxDxH)Differs432 x 660 x 130 mm430 x 660 x 260 mm
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Package dimensions (WxDxH)Known for one603 x 980 x 347 mmUnknown — not stated by the source
FilteringKnown for oneUnknown — not stated by the sourceYes
Mac compatibilityKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons