The APC Smart-UPS RT 8KVA RM 208V with Transformer has 2 kVA more output power capacity than the APC Smart-UPS RT 6000VA Rack Tower 208V (8 kVA vs 6 kVA). The APC Smart-UPS RT 8KVA RM 208V with Transformer has 2,200 W more output power than the APC Smart-UPS RT 6000VA Rack Tower 208V (6400 W vs 4200 W). The APC Smart-UPS RT 8KVA RM 208V with Transformer has 2 min more typical backup time at full load than the APC Smart-UPS RT 6000VA Rack Tower 208V (7.3 min vs 5.3 min). Certification: CSA,FCC Part 15 Class A,UL 1778, RoHS 7b on the APC Smart-UPS RT 6000VA Rack Tower 208V, CSA,FCC Part 15 Class A,UL 1778 on the APC Smart-UPS RT 8KVA RM 208V with Transformer. Input connection type: NEMA L6-30P on the APC Smart-UPS RT 6000VA Rack Tower 208V, 3-wire on the APC Smart-UPS RT 8KVA RM 208V with Transformer.

  • Output power capacity
    • Smart-UPS RT 6000VA Rack Tower 208V:6 kVA
    • Smart-UPS RT 8KVA RM 208V with Transformer:8 kVA
  • Output power
    • Smart-UPS RT 6000VA Rack Tower 208V:4200 W
    • Smart-UPS RT 8KVA RM 208V with Transformer:6400 W
  • Typical backup time at full load
    • Smart-UPS RT 6000VA Rack Tower 208V:5.3 min
    • Smart-UPS RT 8KVA RM 208V with Transformer:7.3 min
  • Typical backup time at half load
    • Smart-UPS RT 6000VA Rack Tower 208V:15.8 min
    • Smart-UPS RT 8KVA RM 208V with Transformer:20 min
  • Battery recharge time
    • Smart-UPS RT 6000VA Rack Tower 208V:2.50 h
    • Smart-UPS RT 8KVA RM 208V with Transformer:2.20 h
  • Weight
    • Smart-UPS RT 6000VA Rack Tower 208V:54.5 kg
    • Smart-UPS RT 8KVA RM 208V with Transformer:158.8 kg
  • Input connection type
    • Smart-UPS RT 6000VA Rack Tower 208V:NEMA L6-30P
    • Smart-UPS RT 8KVA RM 208V with Transformer:3-wire
  • Dimensions (WxDxH)
    • Smart-UPS RT 6000VA Rack Tower 208V:432 x 660 x 130 mm
    • Smart-UPS RT 8KVA RM 208V with Transformer:432 x 736 x 352 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart-UPS RT 6000VA Rack Tower 208V, Smart-UPS RT 8KVA RM 208V with Transformer
27 specifications
Features2 differ
Output power capacityDiffers6 kVA8 kVA
Output powerDiffers4200 W6400 W
Battery3 differ
Typical backup time at full loadDiffers5.3 min7.3 min
Typical backup time at half loadDiffers15.8 min20 min
Battery recharge timeDiffers2.50 h2.20 h
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Designidentical
Cable lengthKnown for one3.05 mUnknown — not stated by the source
Product colourKnown for oneUnknown — not stated by the sourceBlack
Certificates1 differ
CertificationDiffersCSA,FCC Part 15 Class A,UL 1778, RoHS 7bCSA,FCC Part 15 Class A,UL 1778
Weight & dimensions1 differ
WeightDiffers54.5 kg158.8 kg
Other features3 differ
Battery typeKnown for oneLead-AcidUnknown — not stated by the source
Output connectionsDiffers2x NEMA L6-20R 2x NEMA L6-30R1x 3-wire 12x NEMA 5-20R 2x NEMA L6-20R 1x NEMA L6-30R
Input connection typeDiffersNEMA L6-30P3-wire
Dimensions (WxDxH)Differs432 x 660 x 130 mm432 x 736 x 352 mm
Nominal output voltageKnown for one208 VUnknown — not stated by the source
InterfaceKnown for oneUnknown — not stated by the sourceDB-9 RS-232, RJ-45 10/100 Base-T, Smart-Slot