Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS RT 3000VA 208V vs CyberPower CP685AVR uninterruptible power supply (UPS) Line-Interactive 0.685 kVA

Add a product
  • 10specifications compared
  • 8differ
  • 2identical
  • 27known for one product only

Key differences

  • Output power capacity
    • Smart-UPS RT 3000VA 208V:3 kVA
    • CP685AVR uninterruptible power supply (UPS) Line-Interactive 0.685 kVA:0.685 kVA
  • Output power
    • Smart-UPS RT 3000VA 208V:2100 W
    • CP685AVR uninterruptible power supply (UPS) Line-Interactive 0.685 kVA:390 W
  • Typical backup time at full load
    • Smart-UPS RT 3000VA 208V:14.1 min
    • CP685AVR uninterruptible power supply (UPS) Line-Interactive 0.685 kVA:2 min
  • Typical backup time at half load
    • Smart-UPS RT 3000VA 208V:33.9 min
    • CP685AVR uninterruptible power supply (UPS) Line-Interactive 0.685 kVA:10 min
  • Battery recharge time
    • Smart-UPS RT 3000VA 208V:2.50 h
    • CP685AVR uninterruptible power supply (UPS) Line-Interactive 0.685 kVA:8 h
  • Input connection type
    • Smart-UPS RT 3000VA 208V:NEMA L6-30P
    • CP685AVR uninterruptible power supply (UPS) Line-Interactive 0.685 kVA:NEMA 5-15P
  • Dimensions (WxDxH)
    • Smart-UPS RT 3000VA 208V:130 x 660 x 432 mm
    • CP685AVR uninterruptible power supply (UPS) Line-Interactive 0.685 kVA:279.4 x 89 x 165 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of Smart-UPS RT 3000VA 208V, CP685AVR
37 specifications
Features2 differ
Output power capacityDiffers3 kVA0.685 kVA
Output powerDiffers2100 W390 W
Input frequencyKnown for one50/60 HzUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Noise levelKnown for one55 dBUnknown — not stated by the source
Audible alarm(s)YesYes
UPS topologyKnown for oneUnknown — not stated by the sourceLine-Interactive
Surge energy ratingKnown for oneUnknown — not stated by the source890 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Battery3 differ
Typical backup time at full loadDiffers14.1 min2 min
Typical backup time at half loadDiffers33.9 min10 min
Battery recharge timeDiffers2.50 h8 h
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceBB - BP8-12
Designidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
Form factorKnown for oneUnknown — not stated by the sourceCompact
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Certificates1 differ
CertificationDiffersCSA,FCC Part 15 Class A,UL 1778UL1778, cUL, FCC DOC Class B
Weight & dimensionsidentical
WeightKnown for one54.5 kgUnknown — not stated by the source
Other features2 differ
Battery typeKnown for oneLead-AcidUnknown — not stated by the source
InterfaceKnown for oneSmart-SlotUnknown — not stated by the source
Output connectionsKnown for one2x NEMA L6-20R 2x NEMA L6-30RUnknown — not stated by the source
Input connection typeDiffersNEMA L6-30PNEMA 5-15P
Dimensions (WxDxH)Differs130 x 660 x 432 mm279.4 x 89 x 165 mm
Nominal input voltageKnown for one208 VUnknown — not stated by the source
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Output voltage noteKnown for oneConfigurable for 208 or 240 nominal output voltageUnknown — not stated by the source
Operating temperature (T-T)Known for oneUnknown — not stated by the source32 - 95 °F
Dimensions (W x D x H) (imperial)Known for oneUnknown — not stated by the source279.4 x 88.9 x 165.1 mm (11 x 3.5 x 6.5")
Ports & interfacesidentical
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons