The APC Smart-UPS RT 10000VA, Rack Tower, 208V has 4 kVA more output power capacity than the APC Smart-UPS RT 6000VA Rack Tower 208V (10 kVA vs 6 kVA). The APC Smart-UPS RT 10000VA, Rack Tower, 208V has 3,800 W more output power than the APC Smart-UPS RT 6000VA Rack Tower 208V (8000 W vs 4200 W). The APC Smart-UPS RT 6000VA Rack Tower 208V has 0.5 min more typical backup time at full load than the APC Smart-UPS RT 10000VA, Rack Tower, 208V (5.3 min vs 4.8 min). Output connections: 1x 3-wire 2x NEMA L6-20R 2x NEMA L6-30R on the APC Smart-UPS RT 10000VA, Rack Tower, 208V, 2x NEMA L6-20R 2x NEMA L6-30R on the APC Smart-UPS RT 6000VA Rack Tower 208V. Input connection type: 3-wire on the APC Smart-UPS RT 10000VA, Rack Tower, 208V, NEMA L6-30P on the APC Smart-UPS RT 6000VA Rack Tower 208V.

  • Output power capacity
    • Smart-UPS RT 10000VA, Rack Tower, 208V:10 kVA
    • Smart-UPS RT 6000VA Rack Tower 208V:6 kVA
  • Output power
    • Smart-UPS RT 10000VA, Rack Tower, 208V:8000 W
    • Smart-UPS RT 6000VA Rack Tower 208V:4200 W
  • Typical backup time at full load
    • Smart-UPS RT 10000VA, Rack Tower, 208V:4.8 min
    • Smart-UPS RT 6000VA Rack Tower 208V:5.3 min
  • Typical backup time at half load
    • Smart-UPS RT 10000VA, Rack Tower, 208V:14.9 min
    • Smart-UPS RT 6000VA Rack Tower 208V:15.8 min
  • Battery recharge time
    • Smart-UPS RT 10000VA, Rack Tower, 208V:2.20 h
    • Smart-UPS RT 6000VA Rack Tower 208V:2.50 h
  • Weight
    • Smart-UPS RT 10000VA, Rack Tower, 208V:110.9 kg
    • Smart-UPS RT 6000VA Rack Tower 208V:54.5 kg
  • Input connection type
    • Smart-UPS RT 10000VA, Rack Tower, 208V:3-wire
    • Smart-UPS RT 6000VA Rack Tower 208V:NEMA L6-30P
  • Dimensions (WxDxH)
    • Smart-UPS RT 10000VA, Rack Tower, 208V:432 x 736 x 263 mm
    • Smart-UPS RT 6000VA Rack Tower 208V:432 x 660 x 130 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of Smart-UPS RT 10000VA, Rack Tower, 208V, Smart-UPS RT 6000VA Rack Tower 208V
25 specifications
Features2 differ
Output power capacityDiffers10 kVA6 kVA
Output powerDiffers8000 W4200 W
Input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Emergency Power Off (EPO)YesYes
Noise level55 dB55 dB
Audible alarm(s)YesYes
Battery3 differ
Typical backup time at full loadDiffers4.8 min5.3 min
Typical backup time at half loadDiffers14.9 min15.8 min
Battery recharge timeDiffers2.20 h2.50 h
Designidentical
Cable lengthKnown for oneUnknown — not stated by the source3.05 m
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Certificatesidentical
CertificationCSA,FCC Part 15 Class A,UL 1778, RoHS 7bCSA,FCC Part 15 Class A,UL 1778, RoHS 7b
Weight & dimensions1 differ
WeightDiffers110.9 kg54.5 kg
Other features3 differ
Battery typeKnown for oneUnknown — not stated by the sourceLead-Acid
Output connectionsDiffers1x 3-wire 2x NEMA L6-20R 2x NEMA L6-30R2x NEMA L6-20R 2x NEMA L6-30R
Input connection typeDiffers3-wireNEMA L6-30P
Dimensions (WxDxH)Differs432 x 736 x 263 mm432 x 660 x 130 mm
Nominal input voltage208 V208 V
Nominal output voltage208 V208 V
Output voltage noteConfigurable for 208 or 240 nominal output voltageConfigurable for 208 or 240 nominal output voltage
InterfaceKnown for oneDB-9 RS-232, RJ-45 10/100 Base-T, Smart-SlotUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons