Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS RT 10000VA 230V vs CyberPower OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA

Add a product
  • 18specifications compared
  • 12differ
  • 6identical
  • 31known for one product only

Key differences

The APC Smart-UPS RT 10000VA 230V has 8 kVA more output power capacity than the CyberPower OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA (10 kVA vs 2 kVA). The APC Smart-UPS RT 10000VA 230V has 6,200 W more output power than the CyberPower OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA (8000 W vs 1800 W). The CyberPower OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA has 1.8 h more battery recharge time than the APC Smart-UPS RT 10000VA 230V (4 h vs 2.2 h). Input frequency: 47/63 Hz on the APC Smart-UPS RT 10000VA 230V, 40/70 Hz on the CyberPower OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA. Power plug: C20 coupler on the APC Smart-UPS RT 10000VA 230V, C14 coupler on the CyberPower OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA.

  • Output power capacity
    • Smart-UPS RT 10000VA 230V:10 kVA
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:2 kVA
  • Output power
    • Smart-UPS RT 10000VA 230V:8000 W
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:1800 W
  • Input frequency
    • Smart-UPS RT 10000VA 230V:47/63 Hz
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:40/70 Hz
  • Power plug
    • Smart-UPS RT 10000VA 230V:C20 coupler
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:C14 coupler
  • AC outlets quantity
    • Smart-UPS RT 10000VA 230V:8 AC outlet(s)
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:9 AC outlet(s)
  • Battery recharge time
    • Smart-UPS RT 10000VA 230V:2.2 h
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:4 h
  • Form factor
    • Smart-UPS RT 10000VA 230V:Rackmount
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:Rackmount/Tower
  • Rack capacity
    • Smart-UPS RT 10000VA 230V:6U
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:2U

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart-UPS RT 10000VA 230V, OL2000ERTXL2U
49 specifications
Features3 differ
Output power capacityDiffers10 kVA2 kVA
Output powerDiffers8000 W1800 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Known for one160 VUnknown — not stated by the source
Input operation voltage (max)Known for one280 VUnknown — not stated by the source
Input frequencyDiffers47/63 Hz40/70 Hz
Output operation voltage (min)Known for one220 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one7%Unknown — not stated by the source
Noise levelKnown for one55 dBUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Audible alarm modesKnown for oneUnknown — not stated by the sourceBattery replacement
Ports & interfaces2 differ
Power plugDiffersC20 couplerC14 coupler
AC outlets quantityDiffers8 AC outlet(s)9 AC outlet(s)
Number of output IEC jumpersKnown for one4Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Battery1 differ
Number of batteries supportedKnown for one4Unknown — not stated by the source
Battery recharge timeDiffers2.2 h4 h
Typical backup time at full loadKnown for oneUnknown — not stated by the source4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source11 min
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Design2 differ
Form factorDiffersRackmountRackmount/Tower
Rack capacityDiffers6U2U
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneC-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, VDEUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm433 mm
DepthDiffers736 mm600 mm
HeightDiffers263 mm88 mm
WeightDiffers110.9 kg30 kg
Other featuresidentical
Battery typeKnown for oneRBC44Unknown — not stated by the source
Compatible operating systemsKnown for oneUnknown — not stated by the sourceWindows 7 / Vista / XP / 2000, Server 2008 / 2003, Linux
Overload protectionKnown for oneUnknown — not stated by the sourceYes
Packaging dataidentical
Bundled softwareKnown for oneUnknown — not stated by the sourcePowerPanel® Business Edition
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85078000

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.