Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS RC 3000VA vs APC SURT1000XLI+SURTRK uninterruptible power supply (UPS) 1 kVA

Add a product
  • 42specifications compared
  • 19differ
  • 23identical
  • 7known for one product only

Key differences

  • Output power capacity
    • Smart-UPS RC 3000VA:3 kVA
    • SURT1000XLI+SURTRK uninterruptible power supply (UPS) 1 kVA:1 kVA
  • Output power
    • Smart-UPS RC 3000VA:2100 W
    • SURT1000XLI+SURTRK uninterruptible power supply (UPS) 1 kVA:700 W
  • Input frequency
    • Smart-UPS RC 3000VA:45/65 Hz
    • SURT1000XLI+SURTRK uninterruptible power supply (UPS) 1 kVA:50/60 Hz
  • Output operation voltage (max)
    • Smart-UPS RC 3000VA:230 V
    • SURT1000XLI+SURTRK uninterruptible power supply (UPS) 1 kVA:240 V
  • Number of input phases
    • Smart-UPS RC 3000VA:1
    • SURT1000XLI+SURTRK uninterruptible power supply (UPS) 1 kVA:8
  • Number of output phases
    • Smart-UPS RC 3000VA:8
    • SURT1000XLI+SURTRK uninterruptible power supply (UPS) 1 kVA:1
  • Efficiency
    • Smart-UPS RC 3000VA:89%
    • SURT1000XLI+SURTRK uninterruptible power supply (UPS) 1 kVA:88%
  • EMI/RFI noise filtering
    • Smart-UPS RC 3000VA:45 dB
    • SURT1000XLI+SURTRK uninterruptible power supply (UPS) 1 kVA:50 dB

Side by side

Differences highlightedShow differences only (off)
Comparison of Smart-UPS RC 3000VA, SURT1000XLI+SURTRK
49 specifications
Features8 differ
Output power capacityDiffers3 kVA1 kVA
Output powerDiffers2100 W700 W
Input operation voltage (min)100 V100 V
Input operation voltage (max)280 V280 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)220 V220 V
Output operation voltage (max)Differs230 V240 V
Maximum currentKnown for one20 AUnknown — not stated by the source
Surge energy rating420 J420 J
Number of input phasesDiffers18
Number of output phasesDiffers81
EfficiencyDiffers89%88%
Crest factor3:13:1
EMI/RFI noise filteringDiffers45 dB50 dB
Surge protectionYesYes
Surge protection featuresKnown for oneFax, ModemUnknown — not stated by the source
Power protection featuresOverloadOverload
Audible alarm(s)YesYes
Ports & interfaces2 differ
AC outlet typesC13 couplerC13 coupler
Power plugDiffersC20 couplerC14 coupler
AC outlets quantityDiffers9 AC outlet(s)8 AC outlet(s)
RS-232 ports11
Number of output IEC jumpersKnown for oneUnknown — not stated by the source2
Battery2 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Typical backup time at full load1000 min1000 min
Typical backup time at half loadDiffers2 min8 min
Battery recharge timeDiffers2 h3 h
Design1 differ
Form factorRackmountRackmount
Product colourBlackBlack
Rack capacityDiffers4U2U
Cable lengthKnown for one2.4 mUnknown — not stated by the source
Cooling typeActiveActive
Built-in fanYesYes
LED indicatorsPower, StatusPower, Status
Operational conditionsidentical
Storage temperature (T-T)-20 - 50 °C-20 - 50 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneEN/IEC, ISOUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm85 mm
DepthDiffers457 mm483 mm
HeightDiffers175 mm432 mm
WeightDiffers34 kg23 kg
Packaging data1 differ
Package weightDiffers37.7 kg27.8 kg
Other features1 differ
Output connection typeKnown for oneH N + GUnknown — not stated by the source
Package dimensions (WxDxH)Differs622 x 597 x 337 mm630 x 594 x 286 mm
Number of phasesKnown for oneUnknown — not stated by the source9

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.