Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS 1500VA USB vs CyberPower PR1500SWRM2U uninterruptible power supply (UPS) 1.5 kVA

Add a product
  • 14specifications compared
  • 9differ
  • 5identical
  • 23known for one product only

Key differences

  • Output power capacity
    • Smart-UPS 1500VA USB:1.2 kVA
    • PR1500SWRM2U uninterruptible power supply (UPS) 1.5 kVA:1.5 kVA
  • Output power
    • Smart-UPS 1500VA USB:980 W
    • PR1500SWRM2U uninterruptible power supply (UPS) 1.5 kVA:950 W
  • Typical backup time at full load
    • Smart-UPS 1500VA USB:6.7 min
    • PR1500SWRM2U uninterruptible power supply (UPS) 1.5 kVA:5 min
  • Typical backup time at half load
    • Smart-UPS 1500VA USB:23.9 min
    • PR1500SWRM2U uninterruptible power supply (UPS) 1.5 kVA:15 min
  • Battery recharge time
    • Smart-UPS 1500VA USB:3 h
    • PR1500SWRM2U uninterruptible power supply (UPS) 1.5 kVA:8 h
  • Certification
    • Smart-UPS 1500VA USB:UL 1778,VCCI, RoHS 7b
    • PR1500SWRM2U uninterruptible power supply (UPS) 1.5 kVA:UL1778, cUL, FCC DOC Class B
  • Weight
    • Smart-UPS 1500VA USB:25 kg
    • PR1500SWRM2U uninterruptible power supply (UPS) 1.5 kVA:26.3 kg
  • Output connections
    • Smart-UPS 1500VA USB:8x NEMA 5-15R
    • PR1500SWRM2U uninterruptible power supply (UPS) 1.5 kVA:NEMA 5-15R

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart-UPS 1500VA USB, PR1500SWRM2U
37 specifications
Features2 differ
Output power capacityDiffers1.2 kVA1.5 kVA
Output powerDiffers980 W950 W
Surge energy ratingKnown for oneUnknown — not stated by the source1780 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Maximum currentKnown for one12 AUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Ports & interfacesidentical
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source2
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Battery3 differ
Typical backup time at full loadDiffers6.7 min5 min
Typical backup time at half loadDiffers23.9 min15 min
Battery recharge timeDiffers3 h8 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceBB - BP7-12
Designidentical
Cable lengthKnown for one1.83 mUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditionsidentical
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificates1 differ
CertificationDiffersUL 1778,VCCI, RoHS 7bUL1778, cUL, FCC DOC Class B
Weight & dimensions1 differ
WeightDiffers25 kg26.3 kg
Other features2 differ
Output connectionsDiffers8x NEMA 5-15RNEMA 5-15R
Dimensions (WxDxH)Differs170 x 439 x 216 mm438.15 x 400 x 89 mm
Operating temperature (T-T)Known for oneUnknown — not stated by the source32 - 95 °F
Dimensions (W x D x H) (imperial)Known for oneUnknown — not stated by the source438.1 x 400.1 x 88.9 mm (17.2 x 15.8 x 3.5")
Weight (imperial)Known for oneUnknown — not stated by the source26.3 kg (58 lbs)
InterfaceKnown for oneDB-9 RS-232, SmartSlot, USBUnknown — not stated by the source
Nominal input voltageKnown for one100 VUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons