Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA vs CyberPower OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA

Add a product
  • 14specifications compared
  • 11differ
  • 3identical
  • 23known for one product only

Key differences

The CyberPower OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA has 0.56 kVA more output power capacity than the APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA (2 kVA vs 1.44 kVA). The CyberPower OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA has 340 W more output power than the APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA (1320 W vs 980 W). The APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA has 2.4 min more typical backup time at full load than the CyberPower OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA (7.4 min vs 5 min). Input frequency: 50/60 Hz on the APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA, 47/63 Hz on the CyberPower OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA. Certification: CSA,FCC Part 15 Class A,UL 1778 on the APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA, UL1778, cUL 107.1, FCC DOC Class B on the CyberPower OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA.

  • Output power capacity
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:1.44 kVA
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
  • Output power
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:980 W
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:1320 W
  • Input frequency
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:50/60 Hz
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:47/63 Hz
  • Typical backup time at full load
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:7.4 min
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:5 min
  • Typical backup time at half load
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:26.5 min
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:13 min
  • Battery recharge time
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:3 h
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:8 h
  • Weight
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:28.6 kg
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:25.9 kg
  • Output connections
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:6x NEMA 5-15R
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:NEMA 5-20R

Side by side

Differences highlightedShow differences only (off)
Comparison of Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA, OR2200LCDRM2U
37 specifications
Features3 differ
UPS topologyKnown for oneUnknown — not stated by the sourceLine-Interactive
Output power capacityDiffers1.44 kVA2 kVA
Output powerDiffers980 W1320 W
Input frequencyDiffers50/60 Hz47/63 Hz
Surge energy ratingKnown for oneUnknown — not stated by the source1840 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Audible alarm(s)YesYes
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Noise levelKnown for one46 dBUnknown — not stated by the source
Ports & interfacesidentical
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source2
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Battery3 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Typical backup time at full loadDiffers7.4 min5 min
Typical backup time at half loadDiffers26.5 min13 min
Battery recharge timeDiffers3 h8 h
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceBB - BP9-12
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCSA,FCC Part 15 Class A,UL 1778UL1778, cUL 107.1, FCC DOC Class B
Weight & dimensions1 differ
WeightDiffers28.6 kg25.9 kg
Other features3 differ
Output connectionsDiffers6x NEMA 5-15RNEMA 5-20R
Input connection typeDiffersNEMA 5-15PNEMA 5-20P
Dimensions (WxDxH)Differs432 x 457 x 89 mm438.15 x 400 x 89 mm
Operating temperature (T-T)Known for oneUnknown — not stated by the source32 - 95 °F
Dimensions (W x D x H) (imperial)Known for oneUnknown — not stated by the source438.1 x 400.1 x 88.9 mm (17.2 x 15.8 x 3.5")
Weight (imperial)Known for oneUnknown — not stated by the source25.9 kg (57 lbs)
InterfaceKnown for oneDB-9 RS-232, SmartSlot, USBUnknown — not stated by the source
Nominal input voltageKnown for one120 VUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Designidentical
Product colourKnown for oneBlackUnknown — not stated by the source
Cable lengthKnown for one2.44 mUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.