Product comparison · 2 uninterruptible power supplies (upss)

APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA vs CyberPower OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA

Add a product
  • 14specifications compared
  • 11differ
  • 3identical
  • 21known for one product only

Key differences

The CyberPower OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA has 0.06 kVA more output power capacity than the APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA (1.5 kVA vs 1.44 kVA). The APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA has 80 W more output power than the CyberPower OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (980 W vs 900 W). The APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA has 1.4 min more typical backup time at full load than the CyberPower OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (7.4 min vs 6 min). Input frequency: 50/60 Hz on the APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA, 47/63 Hz on the CyberPower OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA. Operating temperature (T-T): 0 - 40 °C on the APC Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA, -20 - 46 °C on the CyberPower OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA.

  • Output power capacity
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:1.44 kVA
    • OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
  • Output power
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:980 W
    • OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:900 W
  • Input frequency
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:50/60 Hz
    • OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:47/63 Hz
  • Typical backup time at full load
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:7.4 min
    • OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:6 min
  • Typical backup time at half load
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:26.5 min
    • OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:18 min
  • Battery recharge time
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:3 h
    • OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:8 h
  • Operating temperature (T-T)
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:0 - 40 °C
    • OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:-20 - 46 °C
  • Weight
    • Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA:28.6 kg
    • OR1500LCDRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:23.6 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart-UPS 1500VA USB & Serial RM 2U 120V NAFTA, OR1500LCDRM2U
35 specifications
Features3 differ
Output power capacityDiffers1.44 kVA1.5 kVA
Output powerDiffers980 W900 W
Input frequencyDiffers50/60 Hz47/63 Hz
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Noise levelKnown for one46 dBUnknown — not stated by the source
UPS topologyKnown for oneUnknown — not stated by the sourceLine-Interactive
Surge energy ratingKnown for oneUnknown — not stated by the source1840 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Battery3 differ
Typical backup time at full loadDiffers7.4 min6 min
Typical backup time at half loadDiffers26.5 min18 min
Battery recharge timeDiffers3 h8 h
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceBB - BP7-12
Designidentical
Product colourKnown for oneBlackUnknown — not stated by the source
Cable lengthKnown for one2.44 mUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 40 °C-20 - 46 °C
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Certificates1 differ
CertificationDiffersCSA,FCC Part 15 Class A,UL 1778UL1778, cUL 107.1, FCC DOC Class B
Weight & dimensions1 differ
WeightDiffers28.6 kg23.6 kg
Other features2 differ
InterfaceKnown for oneDB-9 RS-232, SmartSlot, USBUnknown — not stated by the source
Output connectionsDiffers6x NEMA 5-15RNEMA 5-15R
Dimensions (WxDxH)Differs432 x 457 x 89 mm438.15 x 400 x 89 mm
Nominal input voltageKnown for one120 VUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Operating temperature (T-T)Known for oneUnknown — not stated by the source-4 - 115 °F
Dimensions (W x D x H) (imperial)Known for oneUnknown — not stated by the source438.1 x 400.1 x 88.9 mm (17.2 x 15.8 x 3.5")
Weight (imperial)Known for oneUnknown — not stated by the source23.6 kg (52 lbs)
Ports & interfacesidentical
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source2

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.