Product comparison · 2 uninterruptible power supplies (upss)

APC SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x vs APC SMART UPS 2200 VA RM 2U 120V

Add a product
  • 23specifications compared
  • 10differ
  • 13identical
  • 2known for one product only

Key differences

The APC SMART UPS 2200 VA RM 2U 120V has 0.76 kVA more output power capacity than the APC SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x (2.2 kVA vs 1.44 kVA). The APC SMART UPS 2200 VA RM 2U 120V has 1,000 W more output power than the APC SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x (1980 W vs 980 W). The APC SMART UPS 2200 VA RM 2U 120V has 21 J more surge energy rating than the APC SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x (480 J vs 459 J). Operating relative humidity (H-H): 0 - 95% on the APC SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x, 0 - 90% on the APC SMART UPS 2200 VA RM 2U 120V. Input connection type: NEMA L5-15P on the APC SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x, NEMA 5-15R on the APC SMART UPS 2200 VA RM 2U 120V.

  • Output power capacity
    • SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x:1.44 kVA
    • SMART UPS 2200 VA RM 2U 120V:2.2 kVA
  • Output power
    • SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x:980 W
    • SMART UPS 2200 VA RM 2U 120V:1980 W
  • Surge energy rating
    • SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x:459 J
    • SMART UPS 2200 VA RM 2U 120V:480 J
  • Noise level
    • SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x:46 dB
    • SMART UPS 2200 VA RM 2U 120V:47 dB
  • Typical backup time at full load
    • SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x:7.4 min
    • SMART UPS 2200 VA RM 2U 120V:5.2 min
  • Typical backup time at half load
    • SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x:26.5 min
    • SMART UPS 2200 VA RM 2U 120V:15.7 min
  • Operating relative humidity (H-H)
    • SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x:0 - 95%
    • SMART UPS 2200 VA RM 2U 120V:0 - 90%
  • Package weight
    • SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x:31.9 kg
    • SMART UPS 2200 VA RM 2U 120V:43.6 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of SMART UPS 1500VA RM - 1440VA 980W - 7.4 Minute(s) Full-load - 6 x, SMART UPS 2200 VA RM 2U 120V
25 specifications
Features4 differ
Output power capacityDiffers1.44 kVA2.2 kVA
Output powerDiffers980 W1980 W
Input frequency60 Hz60 Hz
Surge energy ratingDiffers459 J480 J
Emergency Power Off (EPO)YesYes
Noise levelDiffers46 dB47 dB
Audible alarm(s)YesYes
Battery2 differ
Typical backup time at full loadDiffers7.4 min5.2 min
Typical backup time at half loadDiffers26.5 min15.7 min
Battery recharge time3 h3 h
Replacement battery cartridgeKnown for oneRBC24Unknown — not stated by the source
Designidentical
Product colourBlackBlack
Cable length2.44 m2.44 m
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Storage relative humidity (H-H)0 - 95%0 - 95%
Packaging data1 differ
Package weightDiffers31.9 kg43.6 kg
Other features2 differ
InterfaceDB-9/RS-232DB-9/RS-232
Input connection typeDiffersNEMA L5-15PNEMA 5-15R
Dimensions (WxDxH)483 x 457 x 89 mm483 x 457 x 89 mm
Nominal input voltage120 V120 V
Nominal output voltage120 V120 V
Package dimensions (WxDxH)Differs594 x 603 x 251 mm622 x 953 x 254 mm
Battery typeKnown for oneUnknown — not stated by the sourceRBC43

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.