Product comparison · 2 uninterruptible power supplies (upss)

APC Smart UPS 1500VA, 120V, Rack Mount 2U, USB vs CyberPower OL2000RMXL2U uninterruptible power supply (UPS) 2 kVA

Add a product
  • 12specifications compared
  • 8differ
  • 4identical
  • 17known for one product only

Key differences

  • Output power capacity
    • Smart UPS 1500VA, 120V, Rack Mount 2U, USB:1.44 kVA
    • OL2000RMXL2U uninterruptible power supply (UPS) 2 kVA:2 kVA
  • Output power
    • Smart UPS 1500VA, 120V, Rack Mount 2U, USB:980 W
    • OL2000RMXL2U uninterruptible power supply (UPS) 2 kVA:1400 W
  • Input frequency
    • Smart UPS 1500VA, 120V, Rack Mount 2U, USB:50/60 Hz
    • OL2000RMXL2U uninterruptible power supply (UPS) 2 kVA:40/70 Hz
  • Typical backup time at full load
    • Smart UPS 1500VA, 120V, Rack Mount 2U, USB:7.8 min
    • OL2000RMXL2U uninterruptible power supply (UPS) 2 kVA:8 min
  • Typical backup time at half load
    • Smart UPS 1500VA, 120V, Rack Mount 2U, USB:29.4 min
    • OL2000RMXL2U uninterruptible power supply (UPS) 2 kVA:19 min
  • Certification
    • Smart UPS 1500VA, 120V, Rack Mount 2U, USB:UL 1778
    • OL2000RMXL2U uninterruptible power supply (UPS) 2 kVA:UL1449
  • Weight
    • Smart UPS 1500VA, 120V, Rack Mount 2U, USB:28.6 kg
    • OL2000RMXL2U uninterruptible power supply (UPS) 2 kVA:31.8 kg
  • Dimensions (WxDxH)
    • Smart UPS 1500VA, 120V, Rack Mount 2U, USB:483 x 457 x 89 mm
    • OL2000RMXL2U uninterruptible power supply (UPS) 2 kVA:438 x 660.4 x 89 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of Smart UPS 1500VA, 120V, Rack Mount 2U, USB, OL2000RMXL2U
29 specifications
Features3 differ
Output power capacityDiffers1.44 kVA2 kVA
Output powerDiffers980 W1400 W
Input frequencyDiffers50/60 Hz40/70 Hz
Surge energy ratingKnown for oneUnknown — not stated by the source736 J
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Noise levelKnown for one46 dBUnknown — not stated by the source
Ports & interfacesidentical
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source2
Serial ports quantityKnown for oneUnknown — not stated by the source1
Battery2 differ
Typical backup time at full loadDiffers7.8 min8 min
Typical backup time at half loadDiffers29.4 min19 min
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceYUASA - NP7-12
Operational conditionsidentical
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Certificates1 differ
CertificationDiffersUL 1778UL1449
Weight & dimensions1 differ
WeightDiffers28.6 kg31.8 kg
Other features1 differ
Output connectionsKnown for oneUnknown — not stated by the source2x NEMA 5-20R
Input connection typeKnown for oneUnknown — not stated by the sourceNEMA 5-20P
Dimensions (WxDxH)Differs483 x 457 x 89 mm438 x 660.4 x 89 mm
Dimensions (W x D x H) (imperial)Known for oneUnknown — not stated by the source438.1 x 660.4 x 88.9 mm (17.2 x 26 x 3.5")
Weight (imperial)Known for oneUnknown — not stated by the source31.8 kg (70 lbs)
InterfaceKnown for oneDB-9 RS-232, Smart-Slot, USBUnknown — not stated by the source
Nominal input voltageKnown for one120 VUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Designidentical
Product colourKnown for oneBlackUnknown — not stated by the source
Cable lengthKnown for one2.44 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.