Product comparison · 2 uninterruptible power supplies (upss)

APC RT 8000VA vs APC SMT1500X413 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA

Add a product
  • 19specifications compared
  • 9differ
  • 10identical
  • 27known for one product only

Key differences

  • Output power capacity
    • RT 8000VA:8 kVA
    • SMT1500X413 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
  • Output power
    • RT 8000VA:6400 W
    • SMT1500X413 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:980 W
  • Input operation voltage (min)
    • RT 8000VA:220 V
    • SMT1500X413 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:120 V
  • Output operation voltage (min)
    • RT 8000VA:220 V
    • SMT1500X413 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:120 V
  • Battery recharge time
    • RT 8000VA:2.2 h
    • SMT1500X413 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:3 h
  • Width
    • RT 8000VA:263 mm
    • SMT1500X413 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:171 mm
  • Depth
    • RT 8000VA:736 mm
    • SMT1500X413 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:439 mm
  • Height
    • RT 8000VA:432 mm
    • SMT1500X413 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:219 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of RT 8000VA, SMT1500X413
46 specifications
Features4 differ
UPS topologyKnown for oneUnknown — not stated by the sourceLine-Interactive
Output power capacityDiffers8 kVA1.5 kVA
Output powerDiffers6400 W980 W
WaveformKnown for oneUnknown — not stated by the sourceSine
Input operation voltage (min)Differs220 V120 V
Output operation voltage (min)Differs220 V120 V
Output frequency regulationKnown for oneUnknown — not stated by the source47 - 53, 57 - 63 Hz
Surge energy ratingKnown for oneUnknown — not stated by the source459 J
EfficiencyKnown for oneUnknown — not stated by the source97.7%
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceO
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Input operation voltage (max)Known for one240 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Noise levelKnown for one55 dBUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceNEMA 5–15P, NEMA 5–15R
AC outlets quantityKnown for oneUnknown — not stated by the source9 AC outlet(s)
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Battery1 differ
Battery recharge timeDiffers2.2 h3 h
Designidentical
Cable lengthKnown for oneUnknown — not stated by the source1.83 m
Display typeKnown for oneLEDUnknown — not stated by the source
LED indicatorsKnown for oneBattery replacementUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneRoHS 7b Exemption,China RoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers263 mm171 mm
DepthDiffers736 mm439 mm
HeightDiffers432 mm219 mm
WeightDiffers110.9 kg24.1 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source328 mm
Package depthKnown for oneUnknown — not stated by the source595 mm
Package heightKnown for oneUnknown — not stated by the source376 mm
Package weightKnown for oneUnknown — not stated by the source27.2 kg
Other featuresidentical
Output connectionsKnown for oneHard Wire 3-wire (H N + G) IEC 320 C13 IEC 320 C19 IEC JumpersUnknown — not stated by the source
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltage noteKnown for oneConfigurable for 220: 230 or 240Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons