Product comparison · 2 uninterruptible power supplies (upss)

APC Parallel Maintenance Bypass vs Dell PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s)

Add a product
  • 9specifications compared
  • 9differ
  • 0identical
  • 31known for one product only

Key differences

  • Input operation voltage (min)
    • Parallel Maintenance Bypass:220 V
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):160 V
  • Input operation voltage (max)
    • Parallel Maintenance Bypass:400 V
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):286 V
  • Product colour
    • Parallel Maintenance Bypass:Grey
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):Black
  • Width
    • Parallel Maintenance Bypass:1010 mm
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):170 mm
  • Depth
    • Parallel Maintenance Bypass:800 mm
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):380 mm
  • Height
    • Parallel Maintenance Bypass:120 mm
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):216 mm
  • Weight
    • Parallel Maintenance Bypass:100 kg
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):11.6 kg
  • Package weight
    • Parallel Maintenance Bypass:120 kg
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):13.8 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of Parallel Maintenance Bypass, 500W
40 specifications
Features2 differ
Output powerKnown for oneUnknown — not stated by the source500 W
Input operation voltage (min)Differs220 V160 V
Input operation voltage (max)Differs400 V286 V
Output operation voltage (min)Known for oneUnknown — not stated by the source198 V
Output operation voltage (max)Known for oneUnknown — not stated by the source264 V
Surge energy ratingKnown for oneUnknown — not stated by the source2400 J
Response timeKnown for oneUnknown — not stated by the source4 ms
EfficiencyKnown for oneUnknown — not stated by the source95%
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceNetwork
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
AC outlets quantityKnown for oneUnknown — not stated by the source6 AC outlet(s)
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Batteryidentical
Typical backup time at full loadKnown for oneUnknown — not stated by the source5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source12 min
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorKnown for oneUnknown — not stated by the sourceTower
Product colourDiffersGreyBlack
Display typeKnown for oneUnknown — not stated by the sourceLCD
Certificates1 differ
CertificationDiffersEN 50091-2, EN/IEC 62040-1-1, EN/IEC 62040-3, VFI-SS-111FCC, CNS, AS/NZS, KN22, GB, EN, IEC, ANSI, CISPR 22
Weight & dimensions4 differ
WidthDiffers1010 mm170 mm
DepthDiffers800 mm380 mm
HeightDiffers120 mm216 mm
WeightDiffers100 kg11.6 kg
Packaging data1 differ
Package weightDiffers120 kg13.8 kg
Package widthKnown for one1200 mmUnknown — not stated by the source
Package depthKnown for one800 mmUnknown — not stated by the source
Package heightKnown for one1600 mmUnknown — not stated by the source
Other featuresidentical
Number of phasesKnown for oneUnknown — not stated by the source1
Output connectionsKnown for one(1) Hard Wire 3-wire (H N + G) (Battery Backup)Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 9000 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.