Product comparison · 2 uninterruptible power supplies (upss)

APC NetShelter® SX InfraStruXure® System vs APC SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W

Add a product
  • 12specifications compared
  • 6differ
  • 6identical
  • 17known for one product only

Key differences

The APC NetShelter® SX InfraStruXure® System has 5.8 kVA more output power capacity than the APC SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W (8 kVA vs 2.2 kVA). The APC NetShelter® SX InfraStruXure® System has 4,420 W more output power than the APC SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W (6400 W vs 1980 W). The APC SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W has 2.3 h more battery recharge time than the APC NetShelter® SX InfraStruXure® System (4.50 h vs 2.20 h). Input connection type: Hard Wire 3-wire (2PH + G) on the APC NetShelter® SX InfraStruXure® System, NEMA L5-30P on the APC SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W. Dimensions (WxDxH): 600 x 1070 x 1991 mm on the APC NetShelter® SX InfraStruXure® System, 196 x 546 x 432 mm on the APC SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W.

  • Output power capacity
    • NetShelter® SX InfraStruXure® System:8 kVA
    • SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W:2.2 kVA
  • Output power
    • NetShelter® SX InfraStruXure® System:6400 W
    • SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W:1980 W
  • Battery recharge time
    • NetShelter® SX InfraStruXure® System:2.20 h
    • SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W:4.50 h
  • Input connection type
    • NetShelter® SX InfraStruXure® System:Hard Wire 3-wire (2PH + G)
    • SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W:NEMA L5-30P
  • Dimensions (WxDxH)
    • NetShelter® SX InfraStruXure® System:600 x 1070 x 1991 mm
    • SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W:196 x 546 x 432 mm
  • Nominal input voltage
    • NetShelter® SX InfraStruXure® System:208 V
    • SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W:100 V

Side by side

Differences highlightedShow differences only (on)
Comparison of NetShelter® SX InfraStruXure® System, SUA2200JB Smart-UPS 2200VA Tower - 2200VA 1980W
29 specifications
Features2 differ
Output power capacityDiffers8 kVA2.2 kVA
Output powerDiffers6400 W1980 W
Noise levelKnown for one55 dBUnknown — not stated by the source
Input frequencyKnown for oneUnknown — not stated by the source60 Hz
Surge energy ratingKnown for oneUnknown — not stated by the source510 J
Battery1 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery recharge timeDiffers2.20 h4.50 h
Typical backup time at full loadKnown for oneUnknown — not stated by the source6.7 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source24.1 min
Designidentical
Cable lengthKnown for oneUnknown — not stated by the source2.44 m
Operational conditionsidentical
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
CertificationKnown for onecUL,CSA,EIA-310-D,FCC 15 A,ICES-003,Industry Canada,UL 1778,UL 60950,ULUnknown — not stated by the source
Weight & dimensionsidentical
WeightKnown for one289.8 kgUnknown — not stated by the source
Other features3 differ
Output connectionsKnown for one(23) NEMA 5-20R (3) NEMA L5-20R (2) NEMA L6-20R (1) NEMA L6-30RUnknown — not stated by the source
Input connection typeDiffersHard Wire 3-wire (2PH + G)NEMA L5-30P
Dimensions (WxDxH)Differs600 x 1070 x 1991 mm196 x 546 x 432 mm
Nominal input voltageDiffers208 V100 V
Nominal output voltageKnown for one208 VUnknown — not stated by the source
InterfaceKnown for oneUnknown — not stated by the sourceDB-9/RS-232
Mac compatibilityKnown for oneUnknown — not stated by the sourceNo
Relative humidityKnown for oneUnknown — not stated by the source0 - 95%

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons