Product comparison · 2 uninterruptible power supplies (upss)

APC MGE Galaxy 4000 vs Vertiv GXT2-6000RT230 uninterruptible power supply (UPS) 6 kVA

Add a product
  • 9specifications compared
  • 7differ
  • 2identical
  • 20known for one product only

Key differences

  • Output power capacity
    • MGE Galaxy 4000:40 kVA
    • GXT2-6000RT230 uninterruptible power supply (UPS) 6 kVA:6 kVA
  • Output power
    • MGE Galaxy 4000:40000 W
    • GXT2-6000RT230 uninterruptible power supply (UPS) 6 kVA:4200 W
  • Noise level
    • MGE Galaxy 4000:69 dB
    • GXT2-6000RT230 uninterruptible power supply (UPS) 6 kVA:55 dB
  • Operating altitude
    • MGE Galaxy 4000:0 - 999.9 m
    • GXT2-6000RT230 uninterruptible power supply (UPS) 6 kVA:0 - 3000 m
  • Certification
    • MGE Galaxy 4000:cUL,FCC 15 A,UL 1778
    • GXT2-6000RT230 uninterruptible power supply (UPS) 6 kVA:EN62040-1-1; TUV/GS, CE EMC
  • Weight
    • MGE Galaxy 4000:561.4 kg
    • GXT2-6000RT230 uninterruptible power supply (UPS) 6 kVA:67 kg
  • Dimensions (WxDxH)
    • MGE Galaxy 4000:851 x 904 x 1831 mm
    • GXT2-6000RT230 uninterruptible power supply (UPS) 6 kVA:221 x 547 x 430 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of MGE Galaxy 4000, GXT2-6000RT230
29 specifications
Features3 differ
Output power capacityDiffers40 kVA6 kVA
Output powerDiffers40000 W4200 W
Input frequencyKnown for one60 HzUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Noise levelDiffers69 dB55 dB
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Designidentical
Product colourKnown for oneGreyUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Known for one-20 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeDiffers0 - 999.9 m0 - 3000 m
Non-operating altitudeKnown for one0 - 12000 mUnknown — not stated by the source
Certificates1 differ
CertificationDifferscUL,FCC 15 A,UL 1778EN62040-1-1; TUV/GS, CE EMC
Weight & dimensions1 differ
WeightDiffers561.4 kg67 kg
Other features1 differ
Battery typeVRLAVRLA
Dimensions (WxDxH)Differs851 x 904 x 1831 mm221 x 547 x 430 mm
Nominal input voltageKnown for one208 VUnknown — not stated by the source
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Communication options, slotKnown for oneSmartSlot x 2Unknown — not stated by the source
Output connectionsKnown for oneUnknown — not stated by the sourceHardwired + (2) IEC320-C19
Input connection typeKnown for oneUnknown — not stated by the sourceHardwired
Package dimensions (WxDxH)Known for oneUnknown — not stated by the source560 x 690 x 500 mm
Ports & interfacesidentical
Serial ports quantityKnown for oneUnknown — not stated by the source1
Batteryidentical
Typical backup time at full loadKnown for oneUnknown — not stated by the source7 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source18 min
Battery recharge timeKnown for oneUnknown — not stated by the source3 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source76.5 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons