APC Matrix-UPS 3kVA 220/230/240V vs APC Symmetra LX 16kVA

Add a product
  • 16specifications compared
  • 9differ
  • 7identical
  • 14known for one product only

Key differences

The APC Symmetra LX 16kVA has 13 kVA more output power capacity than the APC Matrix-UPS 3kVA 220/230/240V (16 kVA vs 3 kVA). The APC Symmetra LX 16kVA has 8,950 W more output power than the APC Matrix-UPS 3kVA 220/230/240V (11200 W vs 2250 W). The APC Symmetra LX 16kVA has 0.2 min more typical backup time at full load than the APC Matrix-UPS 3kVA 220/230/240V (7.5 min vs 7.3 min). Output connections: (8) IEC 320 C13 on the APC Matrix-UPS 3kVA 220/230/240V, 1xHard Wire 3-wire (H N + G) on the APC Symmetra LX 16kVA. Input connection type: 3-wire on the APC Matrix-UPS 3kVA 220/230/240V, (1PH+N+G)/(3PH + N + G) on the APC Symmetra LX 16kVA.

  • Output power capacity
    • Matrix-UPS 3kVA 220/230/240V:3 kVA
    • Symmetra LX 16kVA:16 kVA
  • Output power
    • Matrix-UPS 3kVA 220/230/240V:2250 W
    • Symmetra LX 16kVA:11200 W
  • Typical backup time at full load
    • Matrix-UPS 3kVA 220/230/240V:7.3 min
    • Symmetra LX 16kVA:7.5 min
  • Typical backup time at half load
    • Matrix-UPS 3kVA 220/230/240V:21.6 min
    • Symmetra LX 16kVA:20.3 min
  • Battery recharge time
    • Matrix-UPS 3kVA 220/230/240V:1.60 h
    • Symmetra LX 16kVA:3 h
  • Weight
    • Matrix-UPS 3kVA 220/230/240V:98.6 kg
    • Symmetra LX 16kVA:307.7 kg
  • Output connections
    • Matrix-UPS 3kVA 220/230/240V:(8) IEC 320 C13
    • Symmetra LX 16kVA:1xHard Wire 3-wire (H N + G)
  • Input connection type
    • Matrix-UPS 3kVA 220/230/240V:3-wire
    • Symmetra LX 16kVA:(1PH+N+G)/(3PH + N + G)

Side by side

Differences highlightedShow differences only (on)
Comparison of Matrix-UPS 3kVA 220/230/240V, Symmetra LX 16kVA
30 specifications
Features2 differ
Output power capacityDiffers3 kVA16 kVA
Output powerDiffers2250 W11200 W
Noise levelKnown for oneUnknown — not stated by the source62 dB
Battery3 differ
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Typical backup time at full loadDiffers7.3 min7.5 min
Typical backup time at half loadDiffers21.6 min20.3 min
Battery recharge timeDiffers1.60 h3 h
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceSYBT5
Operational conditionsidentical
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 4500 m
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceC-tick,CE,EN 50091-1,EN 50091-2,EN 55022 A,EN 55024,EN 60950,GOST,IEC 60950,VDE
Weight & dimensions1 differ
WeightDiffers98.6 kg307.7 kg
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source337.7 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85078000
Total carbon footprint (kg of CO2e)Known for oneUnknown — not stated by the source365.48
Other features3 differ
InterfaceKnown for oneUnknown — not stated by the sourceDB-9, RS-232
Output connectionsDiffers(8) IEC 320 C131xHard Wire 3-wire (H N + G)
Input connection typeDiffers3-wire(1PH+N+G)/(3PH + N + G)
Dimensions (WxDxH)Differs351 x 452 x 683 mm483 x 726 x 937 mm
Output voltage noteKnown for oneUnknown — not stated by the source220-230/240 V
Package dimensions (WxDxH)Known for oneUnknown — not stated by the source599 x 997 x 1181 mm
Nominal input voltageKnown for one230 VUnknown — not stated by the source
I/O portsKnown for one1 x RS-232 1 x SmartUnknown — not stated by the source
Designidentical
Product colourKnown for oneBeigeUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.