Product comparison · 2 uninterruptible power supplies (upss)

APC InfraStruXure® System - 2 Post Rack vs APC SUVTP15KH4B4 uninterruptible power supply (UPS) 15 kVA

Add a product
  • 7specifications compared
  • 6differ
  • 1identical
  • 18known for one product only

Key differences

  • Output power capacity
    • InfraStruXure® System - 2 Post Rack:2.1 kVA
    • SUVTP15KH4B4 uninterruptible power supply (UPS) 15 kVA:15 kVA
  • Output power
    • InfraStruXure® System - 2 Post Rack:2100 W
    • SUVTP15KH4B4 uninterruptible power supply (UPS) 15 kVA:12000 W
  • Battery recharge time
    • InfraStruXure® System - 2 Post Rack:2.50 h
    • SUVTP15KH4B4 uninterruptible power supply (UPS) 15 kVA:5 h
  • Weight
    • InfraStruXure® System - 2 Post Rack:94 kg
    • SUVTP15KH4B4 uninterruptible power supply (UPS) 15 kVA:599.1 kg
  • Dimensions (WxDxH)
    • InfraStruXure® System - 2 Post Rack:510 x 731 x 1991 mm
    • SUVTP15KH4B4 uninterruptible power supply (UPS) 15 kVA:523 x 838 x 1490 mm
  • Nominal input voltage
    • InfraStruXure® System - 2 Post Rack:120 V
    • SUVTP15KH4B4 uninterruptible power supply (UPS) 15 kVA:400 V

Side by side

Differences highlightedShow differences only (on)
Comparison of InfraStruXure® System - 2 Post Rack, SUVTP15KH4B4
25 specifications
Features2 differ
Output power capacityDiffers2.1 kVA15 kVA
Output powerDiffers2100 W12000 W
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Noise levelKnown for one00 dBUnknown — not stated by the source
Battery1 differ
Typical backup time at full loadKnown for oneUnknown — not stated by the source27.4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source66.4 min
Battery recharge timeDiffers2.50 h5 h
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceSYBT4
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Designidentical
Product colourKnown for oneUnknown — not stated by the sourceBlack
Cable lengthKnown for one3.05 mUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 45 °C
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Weight & dimensions1 differ
WeightDiffers94 kg599.1 kg
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source630 kg
Other features2 differ
InterfaceKnown for oneUnknown — not stated by the sourceDB-9/RS-232
Dimensions (WxDxH)Differs510 x 731 x 1991 mm523 x 838 x 1490 mm
Nominal input voltageDiffers120 V400 V
Relative humidityKnown for oneUnknown — not stated by the source0 - 95%
Package dimensions (WxDxH)Known for oneUnknown — not stated by the source650 x 1062 x 1643 mm
Output connectionsKnown for one(15) NEMA 5-15R (2) NEMA 5-20RUnknown — not stated by the source
Input connection typeKnown for oneNEMA L5-30PUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons