Product comparison · 2 uninterruptible power supplies (upss)

APC Galaxy VX 1000kVA Scalable to 1500kVA vs APC Galaxy VX 1250kVA N+1 Redundant UPS

Add a product
  • 42specifications compared
  • 10differ
  • 32identical
  • 3known for one product only

Key differences

  • Output power capacity
    • Galaxy VX 1000kVA Scalable to 1500kVA:1500 kVA
    • Galaxy VX 1250kVA N+1 Redundant UPS:1250 kVA
  • Output power
    • Galaxy VX 1000kVA Scalable to 1500kVA:1500000 W
    • Galaxy VX 1250kVA N+1 Redundant UPS:1250000 W
  • Maximum current
    • Galaxy VX 1000kVA Scalable to 1500kVA:1702 A
    • Galaxy VX 1250kVA N+1 Redundant UPS:2127 A
  • Heat dissipation
    • Galaxy VX 1000kVA Scalable to 1500kVA:174332 BTU/h
    • Galaxy VX 1250kVA N+1 Redundant UPS:217914 BTU/h
  • Storage temperature (T-T)
    • Galaxy VX 1000kVA Scalable to 1500kVA:-15 - 40 °C
    • Galaxy VX 1250kVA N+1 Redundant UPS:0 - 40 °C
  • Width
    • Galaxy VX 1000kVA Scalable to 1500kVA:4400 mm
    • Galaxy VX 1250kVA N+1 Redundant UPS:5600 mm
  • Weight
    • Galaxy VX 1000kVA Scalable to 1500kVA:2910 kg
    • Galaxy VX 1250kVA N+1 Redundant UPS:3990 kg
  • Package width
    • Galaxy VX 1000kVA Scalable to 1500kVA:5160 mm
    • Galaxy VX 1250kVA N+1 Redundant UPS:6640 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of GVX1000K1500HS, GVX1500K1250HS
45 specifications
Features4 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers1500 kVA1250 kVA
Output powerDiffers1500000 W1250000 W
WaveformSineSine
Input operation voltage (min)380 V380 V
Input operation voltage (max)440 V440 V
Input frequency40/70 Hz40/70 Hz
Output operation voltage (min)380 V380 V
Output operation voltage (max)440 V440 V
Output frequency50/60 Hz50/60 Hz
Maximum currentDiffers1702 A2127 A
Heat dissipationDiffers174332 BTU/h217914 BTU/h
Number of input phases33
Number of output phases33
Input power factor11
Crest factor3:13:1
ECO modeYesYes
Output voltage Total Harmonic Distortion (THD)3%3%
Input current Total Harmonic Distortion (THD)3%3%
Noise level68 dB68 dB
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Audible alarm(s)YesYes
Ports & interfacesidentical
AC outlet typesKnown for oneHard Wire 4-wire (3PH + G)Unknown — not stated by the source
SmartSlotYesYes
Batteryidentical
Battery voltage480 V480 V
Designidentical
Form factorLarge towerLarge tower
Product colourWhiteWhite
International Protection (IP) codeIP20IP20
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-15 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 1000 m0 - 1000 m
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersC-tick, CE, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, ETL, IBC 2012, IEC 62040-4, ISTA 2B, REACHC-tick, CE, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, IBC 2012, IEC 62040-4, ISTA 2B, REACH
Weight & dimensions2 differ
WidthDiffers4400 mm5600 mm
Depth900 mm900 mm
Height1970 mm1970 mm
WeightDiffers2910 kg3990 kg
Packaging data2 differ
Package widthDiffers5160 mm6640 mm
Package depth1060 mm1060 mm
Package height2150 mm2150 mm
Package weightDiffers3737 kg5129 kg
Logistics dataidentical
Warranty period1 year(s)1 year(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.