The APC G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA has 92 kVA more output power capacity than the Fujitsu S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA (100 kVA vs 8 kVA). The APC G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA has 82,000 W more output power than the Fujitsu S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA (90000 W vs 8000 W). The APC G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA has 103 V more input operation voltage (min) than the Fujitsu S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA (323 V vs 220 V). Input frequency: 45/65 Hz on the APC G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA, 50/60 Hz on the Fujitsu S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA. Output frequency: 50 Hz on the APC G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA, 50/60 Hz on the Fujitsu S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA.

  • Output power capacity
    • G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:100 kVA
    • S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:8 kVA
  • Output power
    • G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:90000 W
    • S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:8000 W
  • Input operation voltage (min)
    • G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:323 V
    • S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:220 V
  • Input operation voltage (max)
    • G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:477 V
    • S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:415 V
  • Input frequency
    • G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:45/65 Hz
    • S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:50/60 Hz
  • Output operation voltage (max)
    • G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:415 V
    • S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:230 V
  • Output frequency
    • G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:50 Hz
    • S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:50/60 Hz
  • Form factor
    • G55TUPU100HMS uninterruptible power supply (UPS) Double-conversion (Online) 100 kVA:Tower
    • S26361-K915-V802 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:Rackmount/Tower

Side by side

Differences highlightedShow differences only (off)
Comparison of G55TUPU100HMS, S26361-K915-V802
49 specifications
Features7 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers100 kVA8 kVA
Output powerDiffers90000 W8000 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs323 V220 V
Input operation voltage (max)Differs477 V415 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Known for one380 VUnknown — not stated by the source
Output operation voltage (max)Differs415 V230 V
Output frequencyDiffers50 Hz50/60 Hz
Maximum currentKnown for one480 AUnknown — not stated by the source
Number of input phasesKnown for one3Unknown — not stated by the source
Number of output phasesKnown for one3Unknown — not stated by the source
EfficiencyKnown for one93%Unknown — not stated by the source
Input power factorKnown for one1Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one2.5%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Noise levelKnown for one63 dBUnknown — not stated by the source
Power protection featuresKnown for oneOverload, Short circuitUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersHard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + N)C13 coupler, C19 coupler
Serial interfaceKnown for oneYesUnknown — not stated by the source
SmartSlotKnown for oneYesUnknown — not stated by the source
Batteryidentical
Hot-swap batteryYesYes
Automatic battery testKnown for oneYesUnknown — not stated by the source
Design2 differ
Form factorDiffersTowerRackmount/Tower
Product colourDiffersGreyBlack
Display typeLCDLCD
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20, IP32Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 1000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 12000 mUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDECE, CB
Weight & dimensions4 differ
WidthDiffers712 mm432 mm
DepthDiffers855 mm715 mm
HeightDiffers2210 mm263 mm
WeightDiffers588 kg112 kg
Packaging dataidentical
Package widthKnown for one1080 mmUnknown — not stated by the source
Package depthKnown for one1200 mmUnknown — not stated by the source
Package heightKnown for one2330 mmUnknown — not stated by the source
Package weightKnown for one610 kgUnknown — not stated by the source