Product comparison · 2 uninterruptible power supplies (upss)

APC G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA vs APC Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries

Add a product
  • 38specifications compared
  • 22differ
  • 16identical
  • 19known for one product only

Key differences

The APC Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries has 120 kVA more output power capacity than the APC G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA (160 kVA vs 40 kVA). The APC Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries has 124,000 W more output power than the APC G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA (160000 W vs 36000 W). The APC Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries has 17 V more input operation voltage (min) than the APC G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA (340 V vs 323 V). Input frequency: 45/65 Hz on the APC G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA, 40/70 Hz on the APC Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries. AC outlet types: Hard Wire 4-wire (3PH + G) on the APC G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA, Hard Wire 5-wire (3PH + N + G) on the APC Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries.

  • Output power capacity
    • G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:40 kVA
    • Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries:160 kVA
  • Output power
    • G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:36000 W
    • Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries:160000 W
  • Input operation voltage (min)
    • G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:323 V
    • Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries:340 V
  • Input frequency
    • G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:45/65 Hz
    • Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries:40/70 Hz
  • Output operation voltage (min)
    • G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:380 V
    • Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries:230 V
  • Maximum current
    • G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:190 A
    • Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries:80 A
  • Input power factor
    • G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:1
    • Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries:0.99
  • Output voltage Total Harmonic Distortion (THD)
    • G55TUPSU40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:2.5%
    • Symmetra PX 32kW Scalable to 160kW, without Bypass, Distribution, or Batteries:5%

Side by side

Differences highlightedShow differences only (on)
Comparison of G55TUPSU40HB10S, SY32K160H-NB
57 specifications
Features9 differ
Output power capacityDiffers40 kVA160 kVA
Output powerDiffers36000 W160000 W
Input operation voltage (min)Differs323 V340 V
Input frequencyDiffers45/65 Hz40/70 Hz
Output operation voltage (min)Differs380 V230 V
Output frequency regulationKnown for oneUnknown — not stated by the source+/- 3 Hz
Maximum currentDiffers190 A80 A
Number of output phasesKnown for oneUnknown — not stated by the source3
EfficiencyKnown for oneUnknown — not stated by the source95%
Input power factorDiffers10.99
Output voltage Total Harmonic Distortion (THD)Differs2.5%5%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Noise levelDiffers55.5 dB63 dB
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload, Short circuit
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Low battery alarm
Crest factorKnown for one3:1Unknown — not stated by the source
Web-based managementKnown for oneYesUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersHard Wire 4-wire (3PH + G)Hard Wire 5-wire (3PH + N + G)
RS-232 portsKnown for oneUnknown — not stated by the source1
Power plugKnown for oneTerminalUnknown — not stated by the source
AC outlets quantityKnown for one1 AC outlet(s)Unknown — not stated by the source
Batteryidentical
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceSYPBV96K160H
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery voltageKnown for one432 VUnknown — not stated by the source
Battery life (max)Known for one10 year(s)Unknown — not stated by the source
Battery recharge timeKnown for one10 hUnknown — not stated by the source
Design1 differ
Product colourDiffersGreyBlack
Rack capacityKnown for oneUnknown — not stated by the source42U
Operational conditions2 differ
Storage temperature (T-T)Differs-20 - 45 °C-15 - 40 °C
Non-operating altitudeDiffers0 - 12000 m0 - 15000 m
Packaging contentidentical
Quick installation guideKnown for oneYesUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDEEN 50091-1, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, ISO 14001, ISO 9001, VFI-SS-111
Weight & dimensions4 differ
WidthDiffers1110 mm600 mm
DepthDiffers855 mm1070 mm
HeightDiffers1900 mm1991 mm
WeightDiffers958 kg382 kg
Packaging data4 differ
Package widthDiffers1130 mm848 mm
Package depthDiffers960 mm1210 mm
Package heightDiffers2030 mm2140 mm
Package weightDiffers978 kg421 kg