Product comparison · 2 uninterruptible power supplies (upss)

APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA vs APC Image MGE Galaxy 5500

Add a product
  • 36specifications compared
  • 17differ
  • 19identical
  • 18known for one product only

Key differences

The APC Image MGE Galaxy 5500 has 90 V more input operation voltage (min) than the APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA (340 V vs 250 V). The APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA has 17 V more input operation voltage (max) than the APC Image MGE Galaxy 5500 (477 V vs 460 V). The APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA has 113 A more maximum current than the APC Image MGE Galaxy 5500 (190 A vs 77 A). International Protection (IP) code: IP20 on the APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA, IP22 on the APC Image MGE Galaxy 5500. Operating altitude: 0 - 1000 m on the APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA, 0 - 999.9 m on the APC Image MGE Galaxy 5500.

  • Input operation voltage (min)
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:250 V
    • Image MGE Galaxy 5500:340 V
  • Input operation voltage (max)
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:477 V
    • Image MGE Galaxy 5500:460 V
  • Maximum current
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:190 A
    • Image MGE Galaxy 5500:77 A
  • Efficiency
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:92.7%
    • Image MGE Galaxy 5500:91%
  • Output voltage Total Harmonic Distortion (THD)
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:2%
    • Image MGE Galaxy 5500:2.5%
  • Noise level
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:55.5 dB
    • Image MGE Galaxy 5500:65 dB
  • International Protection (IP) code
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:IP20
    • Image MGE Galaxy 5500:IP22
  • Operating altitude
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:0 - 1000 m
    • Image MGE Galaxy 5500:0 - 999.9 m

Side by side

Differences highlightedShow differences only (off)
Comparison of G55TUPSM40HB10S, Image MGE Galaxy 5500
54 specifications
Features6 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacity40 kVA40 kVA
Output power36000 W36000 W
WaveformSineSine
Input operation voltage (min)Differs250 V340 V
Input operation voltage (max)Differs477 V460 V
Input frequency45/65 Hz45/65 Hz
Output operation voltage (min)380 V380 V
Output operation voltage (max)415 V415 V
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentDiffers190 A77 A
EfficiencyDiffers92.7%91%
Power factorKnown for one1Unknown — not stated by the source
Crest factor3:13:1
Output voltage Total Harmonic Distortion (THD)Differs2%2.5%
Input current Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Noise levelDiffers55.5 dB65 dB
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Number of input phasesKnown for oneUnknown — not stated by the source3
Number of output phasesKnown for oneUnknown — not stated by the source3
Input power factorKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlet typesKnown for oneHard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + N)Unknown — not stated by the source
AC outlets quantityKnown for one2 AC outlet(s)Unknown — not stated by the source
SmartSlotYesYes
Power plugKnown for oneUnknown — not stated by the sourceTerminal
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery life (max)10 year(s)10 year(s)
Battery recharge timeKnown for one10 hUnknown — not stated by the source
Design1 differ
Form factorTowerTower
Product colourGreyGrey
Display typeLCDLCD
LED indicatorsYesYes
International Protection (IP) codeDiffersIP20IP22
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-20 - 45 °C-20 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeDiffers0 - 1000 m0 - 999.9 m
Non-operating altitude0 - 12000 m0 - 12000 m
Certificates1 differ
CertificationDiffersCE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDECE, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 62040-2, ISO 9001, TUV, VDE
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers1110 mm712 mm
DepthDiffers850 mm855 mm
HeightDiffers1900 mm2210 mm
WeightDiffers888 kg488 kg
Packaging data4 differ
Package widthDiffers1130 mm1080 mm
Package depthDiffers960 mm1200 mm
Package heightDiffers2030 mm2340 mm
Package weightDiffers978 kg510 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other featuresidentical
Type of input protection requiredKnown for oneUnknown — not stated by the sourcegL fuse
BypassKnown for oneUnknown — not stated by the sourceBuilt-in Maintenance Bypass, Built-in Static Bypass, Optional External Bypass