Product comparison · 2 uninterruptible power supplies (upss)

APC G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA vs APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA

Add a product
  • 40specifications compared
  • 20differ
  • 20identical
  • 11known for one product only

Key differences

The APC G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA has 80 kVA more output power capacity than the APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA (120 kVA vs 40 kVA). The APC G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA has 72,000 W more output power than the APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA (108000 W vs 36000 W). The APC G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA has 130 V more input operation voltage (min) than the APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA (380 V vs 250 V). Output frequency: 50 Hz on the APC G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA, 50/60 Hz on the APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA. AC outlets quantity: 1 AC outlet(s) on the APC G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA, 2 AC outlet(s) on the APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA.

  • Output power capacity
    • G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:120 kVA
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:40 kVA
  • Output power
    • G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:108000 W
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:36000 W
  • Input operation voltage (min)
    • G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:380 V
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:250 V
  • Input operation voltage (max)
    • G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:415 V
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:477 V
  • Output frequency
    • G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:50 Hz
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:50/60 Hz
  • Maximum current
    • G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:480 A
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:190 A
  • Efficiency
    • G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:93%
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:92.7%
  • Output voltage Total Harmonic Distortion (THD)
    • G55TUPM120HMS uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA:2.5%
    • G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA:2%

Side by side

Differences highlightedShow differences only (off)
Comparison of G55TUPM120HMS, G55TUPSM40HB10S
51 specifications
Features9 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers120 kVA40 kVA
Output powerDiffers108000 W36000 W
WaveformSineSine
Input operation voltage (min)Differs380 V250 V
Input operation voltage (max)Differs415 V477 V
Input frequency45/65 Hz45/65 Hz
Output operation voltage (min)380 V380 V
Output operation voltage (max)415 V415 V
Output frequencyDiffers50 Hz50/60 Hz
Maximum currentDiffers480 A190 A
EfficiencyDiffers93%92.7%
Crest factor3:13:1
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Differs2.5%2%
Input current Total Harmonic Distortion (THD)3%3%
Noise levelDiffers63 dB55.5 dB
Auto-restartKnown for oneYesUnknown — not stated by the source
Power factorKnown for oneUnknown — not stated by the source1
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Ports & interfaces2 differ
AC outlet typesDiffersHard Wire 4-wire (3PH + G)Hard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + N)
Power plugKnown for oneTerminalUnknown — not stated by the source
AC outlets quantityDiffers1 AC outlet(s)2 AC outlet(s)
SmartSlotYesYes
Batteryidentical
Battery life (max)10 year(s)10 year(s)
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Battery recharge timeKnown for oneUnknown — not stated by the source10 h
Design1 differ
Form factorTowerTower
Product colourGreyGrey
Display typeLCDLCD
LED indicatorsYesYes
International Protection (IP) codeDiffersIP32, IP20IP20
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-20 - 45 °C-20 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 1000 m0 - 1000 m
Non-operating altitude0 - 12000 m0 - 12000 m
Certificatesidentical
CertificationCE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDECE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDE
Weight & dimensions4 differ
WidthDiffers712 mm1110 mm
DepthDiffers855 mm850 mm
HeightDiffers2210 mm1900 mm
WeightDiffers588 kg888 kg
Packaging data4 differ
Package widthDiffers1080 mm1130 mm
Package depthDiffers1200 mm960 mm
Package heightDiffers2340 mm2030 mm
Package weightDiffers610 kg978 kg
Logistics dataidentical
Products per palletKnown for one1 pc(s)Unknown — not stated by the source
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85078000

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons